5.  Registration is complete when the Receiver receives the probe temperature and displays it in place of the 

flashing icon 

- - -

. If the probe temperature does not appear in the receiver within 5-10 seconds, press and 

hold [MODE] button in the Receiver unit for 2 seconds to re-enter the RF registration mode. The icon 

- - 

-

 will start to flash. Then press and hold [TX] button in the transmitter for 2 seconds to force it to send the 

registration code to the receiver. 

 

 
HELPFUL HINTS 

- The display temperature range is 14

°

F to 482

°

F (-10

°

 to 250

°

C). 

LLL

 will be displayed on the screen when 

the internal temperature of the meat is lower than 14

°

F (-10

°

C) and 

HHH

 will flash when the temperature is 

above 482

°

F (250

°

C). This is not a malfunction. 

LLL

 will also appear when the stainless steel probe is disconnected or malfunctions. 

- If the receiver and/or the transmitter display 

LLL

 or 

HHH

 instead of the probe temperature, wait for probe to 

reach room temperature. If 

LLL

 or 

HHH

 is still displayed, it is likely the internal probe wire has shorted out 

either through moisture or heat damage. 

- Do not immerse the probe in water while cleaning. 
- Do not allow the probe or probe wire to come into contact with flames. If cooking with grill cover 
closed, use only medium or low heat. 

- Make sure the probe tip is inserted into the meat at least 2.5 cm / 1 inch. 

- If the temperature displayed seems to read too high or the temperature seems to be increasing too quickly, 

check to make sure that the probe tip is not poking through the food to the outside. Reposition the probe tip in 

the centre of the thickest part of the food. Avoid touching bone or heavy fat areas. 

 

Cautions: 

- Always wear a heat resistant glove to touch the stainless steel probe sensor or wire during or just after cooking. 

Do not touch with bare hands. 

- Keep the stainless steel probe sensor and wire away from children. 

- Clean the stainless steel probe and dry thoroughly after each and every use. 

- Do not use the receiver in the rain. It is not waterproof. 

- Do not expose the plug of the stainless steel probe or the plug-in hole of the transmitter to water or any liquid. 

This will result in a bad connection and faulty readings. 

- Do not expose the receiver or transmitter to direct heat or surface. 

- Do not use stainless steel probe in a microwave oven. 

- The Remote Thermometer registers temperatures as low as 14

°

F (-10

°

C) and as high 482

°

F (250

°

C). 

LLL

 

will be displayed below 14

°

F (-10

°

C) and 

HHH

 will be displayed above 482

°

F (250

°

C). 

- Do not use the stainless steel probe sensor above 482

°

F (250

°

C). Doing so will deteriorate the wire. 

 

 

 

Содержание TPR303

Страница 1: ...reaching the target temperature Receiver Features LCD Liquid crystal display to show display icons Food Taste Timer Received Set temperatures See LCD diagram for detailed information CLIP Detachable c...

Страница 2: ...will appear in the place of the probe temperature and flash in 1Hz press Mode button again to stop the RF registration 5 START STOP Press to start or stop the timer count down or count up Press to sto...

Страница 3: ...t 0 00 and starts beeping for 20 seconds to alert the user To stop the alert sound press the START STOP button How to use the count down timer 1 With the unit in Timer mode and the timer is stop runni...

Страница 4: ...erature of 170 F display automatically MEAT TASTE Type English French WELL DONE MEDIUM MEDIUM RARE RARE Beef BEEF BOEUF 170 F 160 F 145 F 140 F Veal VEAL VEAU 170 F 160 F 145 F N A Lamb LAMB AGNEA 170...

Страница 5: ...p once every 2 seconds and last for 1 minute Reach Alert When the probe temperature reaches the pre set temperature the device unit will beep in pattern of bi bi bi sec for 5 second then silent for 7...

Страница 6: ...this loss link condition persists more than 3 minutes the device will start to alert user by emitting a beep sound once for every 2 seconds for a duration of 10 minutes prompting the user to correct...

Страница 7: ...eiver unit Device Temperature measuring range 14 F to 482 F 10 C to 250 C Displayed probe temperature range 14 F to 482 F 10 C to 250 C Operating temperature device 32 F to 122 F 0 C to 50 C Batteries...

Страница 8: ...ometer requires the Receiver to link up with the Transmitter unit through signal registration Please follow below procedures to make sure the receiver can synchronize with the transmitter signal 1 Ins...

Страница 9: ...tact with flames If cooking with grill cover closed use only medium or low heat Make sure the probe tip is inserted into the meat at least 2 5 cm 1 inch If the temperature displayed seems to read too...

Страница 10: ...accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment do...

Отзывы: