Ewig TPR303 Скачать руководство пользователя страница 4

  

Page 4 of 10 

 

Thermometer mode 

 

Pre-programmed Temperature Alert 

In  Thermometer  mode,  this  device  will  alert  user  when  the  probe  temperature  reached  the  pre-determined 

selective setting. 

 

The user firstly selects a meat type (e.g. Beef) and a taste level (e.g. WELL DONE). The pre-set temperature of 

170

º

F display automatically.  

 

MEAT 

TASTE 

Type 

English 

French 

WELL 

DONE  MEDIUM 

MEDIUM 

RARE 

RARE 

Beef 

BEEF 

BOEUF 

170

º

160

º

145

º

140

º

Veal 

VEAL 

VEAU 

170

º

160

º

145

º

N/A 

Lamb 

LAMB 

AGNEA 

170

º

160

º

145

º

N/A 

Pork 

PORK 

PORC 

170

º

160

º

N/A 

N/A 

Chicken, whole 

CHICK 

POUL 

185

º

N/A 

N/A 

N/A 

Turkey, whole 

TURKY 

DINDE 

185

º

N/A 

N/A 

N/A 

Ham pre-cooked 

HAM 

JAMBO 

140

º

N/A 

N/A 

N/A 

Low battery indicator 

for receiver 

Low battery indicator 

for transmitter 

Meat type 

Taste level 

Содержание TPR303

Страница 1: ...reaching the target temperature Receiver Features LCD Liquid crystal display to show display icons Food Taste Timer Received Set temperatures See LCD diagram for detailed information CLIP Detachable c...

Страница 2: ...will appear in the place of the probe temperature and flash in 1Hz press Mode button again to stop the RF registration 5 START STOP Press to start or stop the timer count down or count up Press to sto...

Страница 3: ...t 0 00 and starts beeping for 20 seconds to alert the user To stop the alert sound press the START STOP button How to use the count down timer 1 With the unit in Timer mode and the timer is stop runni...

Страница 4: ...erature of 170 F display automatically MEAT TASTE Type English French WELL DONE MEDIUM MEDIUM RARE RARE Beef BEEF BOEUF 170 F 160 F 145 F 140 F Veal VEAL VEAU 170 F 160 F 145 F N A Lamb LAMB AGNEA 170...

Страница 5: ...p once every 2 seconds and last for 1 minute Reach Alert When the probe temperature reaches the pre set temperature the device unit will beep in pattern of bi bi bi sec for 5 second then silent for 7...

Страница 6: ...this loss link condition persists more than 3 minutes the device will start to alert user by emitting a beep sound once for every 2 seconds for a duration of 10 minutes prompting the user to correct...

Страница 7: ...eiver unit Device Temperature measuring range 14 F to 482 F 10 C to 250 C Displayed probe temperature range 14 F to 482 F 10 C to 250 C Operating temperature device 32 F to 122 F 0 C to 50 C Batteries...

Страница 8: ...ometer requires the Receiver to link up with the Transmitter unit through signal registration Please follow below procedures to make sure the receiver can synchronize with the transmitter signal 1 Ins...

Страница 9: ...tact with flames If cooking with grill cover closed use only medium or low heat Make sure the probe tip is inserted into the meat at least 2 5 cm 1 inch If the temperature displayed seems to read too...

Страница 10: ...accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment do...