19
7.0 O p eration
7.0 Operation
7.1 Safety
DANGER
Risk of crushing
While moving onto solid objects, the force of the device may
cause injuries.
Therefore:
• Ensure that there are no persons in the stroke area of the device
while in operation.
• Take note of maximum permissible operating parameters for de-
vice(see Data sheets in 11 Appendix).
• Do not touch elements connected to the device while the device
is in operation.
DANGER
If a part of the linear module fails (belt breaking, screw fracture,
loss of input torque), the working mass will drop.
Therefore:
• Additional safety features must be in place to protect the work-
place.
• Where there is no input torque, and safe brake is loosened the
carriage can be moved manually or by gravity, particularly for ver-
tical application.
• Check the drive regularly for signs or excessive wear (see Mainte-
nance work).
NOTICE
Material damage due to static and dynamic overload of the
device.
Static and dynamic overload can damage the device and cause
it to fail.
Therefore:
1. Adhere to maximum permissible operating parameters
for the device (see data sheet in 11 Appendix).
2. Never exceed nominal load.
WARNING
Burn hazard. Do not touch the surface of the device while
operating.
WARNING
If liquids or dusts penetrate the linear module during operation,
it can be damaged or will not operate properly. Keep liquid and
dust away.
7.2 Normal operation
The CLSM linear module can be operated by a controller
such as PC and PLC. The user gives a command to the pro-
gram to send signals to the motor drive and operate the
motor.
Before use, the device users may need to set the parameter
like origin position, velocity and acceleration value.
Note
The device does not feature its own operating control elements.
The operation takes place through separate operating element.
7.3 Action before use
Ensure that there are no persons or objects in the stroke
area of the device.
Before using the device, make sure that the parts of the de-
vice and surrounding environment are clean and not
explosive.
It should be used in a place free from water and dust.
NOTICE
Contamination of the devices can cause serious damage.
Therefore:
• Clean dirty parts immediately after they become dirty
(see 8.2.1 Cleaning ).
7.4 Emergency
disengagement
Note
The CLSM linear module has no emergency disengagement
function.
Safety devices have to be available to protect persons and
properties. In emergency situations, workers have to be able
to push emergency stop switches to stop the device.
In case of an accident, stop the device immediately, call the
medical Staff, and start emergency treatment.