9
3.0 Te chnic al data
9
NOTE
The technical data (dimensions, weight, output, connection
values etc.) can be found in the enclosed drawings and data
sheets (⮑ 11 Appendix, page 25).
3.1 Operating conditions
Environment
Information
Value
Unit
Temperature range
–40 to +85 °C
Relative atmospheric humidity
(no build up of condensation)
up to 95
%
Duration (intermittent)
Information
Value
Unit
Maximum operating time without a break 1
Cycles
Break until next operation
3
Times of
operating
time
Max duty cycle at rated load: 25% Max. (120 s on/ 360 s off)
3.2 Product label
The product label provides the following information
Fig. 1
1
2
3
4
5
6
7
8
9
10
3.0 Technical data
1. Identification of actuator (type key)
2. Part number
3. Customer part number
4. Performance (power voltage, rated current, rated load,
speed with rated load)
5. Duty cycle
6. Serial number
7. IP level
8. Manufacturer or the country of origin
9. CE mark
10. RoHS mark