EWA CORELIS PXIE-1149.1/4E Скачать руководство пользователя страница 4

 

ii 

 

EXCLUSIVE REMEDIES 

THE  REMEDIES  CONTAINED  HEREIN  ARE  THE  CUSTOMER'S  SOLE  AND 

EXCLUSIVE  REMEDIES.    CORELIS  SHALL  NOT  BE  LIABLE  FOR  ANY  DIRECT, 
INDIRECT,  SPECIAL,  INCIDENTAL,  OR  CONSEQUENTIAL  DAMAGES,  WHETHER 
BASED ON CONTRACT, TORT, OR ANY OTHER LEGAL THEORY. 
Product maintenance agreements and other customer assistance agreements are available for Corelis 
products.  For assistance, contact your nearest Corelis Sales and Service Office. 
 

RETURN POLICY 

No items returned to CORELIS for warranty, service, or any other reason shall be accepted unless 
first  authorized  by  CORELIS,  either  directly  or  through  its  authorized  sales  representatives.    All 

returned items must be shipped pre-paid and clearly display a Returned Merchandise Authorization 
(RMA) number on the shipping carton.  Freight-collect items will NOT be accepted.  Customers or 

authorized  sales  representatives  must  first  contact  CORELIS  with  notice  of  request  for  return  of 
merchandise.    RMA's  can  only  originate  from  CORELIS.    If  authorization  is  granted,  an  RMA 

number  will  be  forwarded  to  the  customer  either  directly  or  through  its  authorized  sales 
representative. 
 

CONTACT INFORMATION  

For sales inquiries, please contact 

[email protected]

 

For any support related questions, please enter a support request at 

www.corelis.com/support

 or 

email 

[email protected]

. 

For  more  information  about  other  products  and  services  that  Corelis  offers,  please  visit 

www.corelis.com

.

Содержание CORELIS PXIE-1149.1/4E

Страница 1: ...49 1 4E PXIE 1149 1 4E High Speed PXIE Boundary Scan Controller User s Manual Copyright 2019 Corelis Inc Corelis Inc 13100 Alondra Blvd Suite 102 Cerritos CA 90703 2262 Telephone 562 926 6727 Fax 562 404 6196 ...

Страница 2: ......

Страница 3: ...s reserved No part of this document may be reproduced or translated to other languages without the prior written consent of CORELIS This manual is a CORELIS proprietary document and may not be transferred to another party without the prior written permission of CORELIS CORELIS assumes no responsibility for the use of or reliability of its software on equipment that is not furnished by CORELIS ENVI...

Страница 4: ...rized sales representatives All returned items must be shipped pre paid and clearly display a Returned Merchandise Authorization RMA number on the shipping carton Freight collect items will NOT be accepted Customers or authorized sales representatives must first contact CORELIS with notice of request for return of merchandise RMA s can only originate from CORELIS If authorization is granted an RMA...

Страница 5: ...ts 5 PXIE 1149 1 4E Electrical Specifications 6 JTAG TAP Interface 6 Chapter 2 PXIE 1149 1 4E Installation 7 Software Must Be Installed 7 PXIE 1149 1 4E Hardware Installation 7 Installation Steps 7 Chapter 3 Connecting to the Target 11 Connecting to the Target 11 Connecting the TAP Signals 13 Chapter 4 Using the PXIE 1149 1 4E with ScanExpress 15 Hardware Setup 15 Using PXIE 1149 1 4E with ScanExp...

Страница 6: ...iv 20 pin TAP Connector 29 Appendix B Self Test Utility Software 33 Self Test 33 ...

Страница 7: ...TAP Connectors 11 Figure 4 1 Controller Configuration Screen 15 Figure 4 2 PXIE 1149 1 4E Setup Screen 16 Figure A 1 Standard TAP connector top view 23 Figure A 2 TAP Connector Schematic 25 Figure A 3 Boundary scan Flash Programming 16 Pin TAP Connector top view 26 Figure A 4 Flash Programming TAP Connector Schematics 28 Figure A 5 Boundary scan Flash Programming 20 Pin TAP Connector top view 29 F...

Страница 8: ...ts Default 13 Table 3 2 I2C SPI Connector Pin Assignments Default 14 Table A 1 Signal Description and Termination 24 Table A 2 Standard 10 Pin TAP Connector 24 Table A 3 Flash Programming TAP 16 Pin Connector 27 Table A 4 Signal Description and Termination 27 Table A 5 Flash Programming TAP 20 Pin Connector 30 Table A 6 Signal Description and Termination 30 ...

Страница 9: ...ipped with a PXIE bus and any IEEE Standard 1149 1 compatible target The PXIE 1149 1 4E is designed to control the operation of an IEEE Standard 1149 1 boundary scan JTAG test access port TAP by generating the proper signals under software control to interface with the target device It contains memory behind the pin architecture and supports scan operations at continuous JTAG clock TCK speeds of u...

Страница 10: ...ler that can access devices boards or systems that are compliant with IEEE Standard 1149 1 The PXIE bus compatible card supports up to four JTAG boundary scan chains TAPs In addition three general purpose bi directional discrete I O signals per TAP can test or control non boundary scan areas of the unit under test UUT The discrete I O signals can also assist in greatly expediting certain long scan...

Страница 11: ...ctor drivers they can readily tie to similar target signals without the need to alter its circuitry yet still gain control of related functions such as a Flash write signal As outputs these discrete signals are useful for providing control functions on the user target system such as general reset power control device write pulse disable enable and or similar signals for non boundary scan target st...

Страница 12: ... rate on the outputs Software Pin Configuration The PXIE 1149 1 4E s pins are remappable in the ScanExpress software Pin Protection The PXIE 1149 1 4E features voltage detection circuitry to prevent the drivers from being damaged if the outputs are inadvertently shorted to power or ground ...

Страница 13: ...ent Temperature 0 C to 55 C Relative Humidity 10 to 90 non condensing Storage Environment Temperature 40 C to 85 C Host Interface PXI interface 3U slot using 1 lane of PCIE Required Host CPU Pentium III 1GHz or better Required Operating System Windows 7 Windows 10 Power Requirements 12V 3 3V Provided by the PXI interface No external power supply needed ...

Страница 14: ... MHz Maximum TCK Frequency 75 MHz TCK Frequency Steps 0 05 MHz increments between 0 05 and 1 MHz 0 50 MHz increments between 1 and 15 MHz 1 0 MHz increments between 15 and 75 MHz Maximum scanning data length unlimited Programmable Voltage V_adj Range 1 25V to 3 3V in 0 05V steps Symbol Test Conditions Limit Min Limit Max Units VIH V_adj 2 7 V 2 V_adj 0 5 V V_adj 2 7 V 0 65 V_adj V_adj 0 5 V VIL V_...

Страница 15: ...XIE 1149 1 4E module Obtain the ScanExpress CD ROM or any other Corelis application that supports the PXIE 1149 1 4E module in order to proceed with installation Install the PXIE 1149 1 4E controller before installing the ScanExpress Application Software PXIE 1149 1 4E Hardware Installation To install the PXIE 1149 1 4E on a host PC follow the installation steps below Plug in the PXIE 1149 1 4E co...

Страница 16: ...nstallation 8 3 The Found New Hardware Wizard dialog box will automatically start as shown below in Figure 2 1 4 Select No not this time as shown below and click on the Next button Figure 2 1 Found New Hardware Wizard ...

Страница 17: ...the software automatically Recommended and click on the Next button Figure 2 2 Found New Hardware Wizard 6 After the necessary files are copied to the system the following dialog box Figure 2 3 will pop up indicating that the device driver is successfully installed Figure 2 3 Installation Successfully Completed ...

Страница 18: ...ter icon and then select Properties Choose the Hardware tab and click on the Device Manager button Corelis USB 1149 1 4E JTAG Controller should be listed in the Universal Serial Bus controller section as shown in Figure 2 4 Figure 2 4 Windows Device Manager Congratulations The PXIE 1149 1 4E drivers have now been successfully installed on your computer and the controller is now ready to be used We...

Страница 19: ... connection to the target board system is through the TAP connectors on the front of the PXIE 1149 1 4E Figure 3 1 shows the front view of the PXIE 1149 1 4E box including the four TAP connectors which are clearly marked on the cable TAP 1 TAP 2 TAP 3 and TAP 4 Figure 3 1 PXIE 1149 1 4E 80 pin TAP Connectors ...

Страница 20: ...et power ON ALERT Make sure your target board is connected to GROUND prior to powering up the target board This assures that the target power return flows through its power supply return GND signal and not through the ground wire of the PXIE Otherwise with a floating target if the user hot plugs the target power cable from its external supply such as a brick type power supply there is no guarantee...

Страница 21: ...figurations Pin Signal Name Signal Description 1 TRST Test Reset Input to the UUT 2 GND 3 TDI Test Data In Input to the UUT 4 GND 5 TDO Test Data Out Output from the UUT 6 GND 7 TMS Test Mode Select Input to the UUT 8 GND 9 TCK Test Clock Input to the UUT 10 GND 11 IO1 Discrete Input Output to the UUT 12 GND 13 IO2 Discrete Input Output to the UUT 14 GND 15 IO3 Discrete Input Output to the UUT 16 ...

Страница 22: ... 4 GND 5 MISO SPI Serial Out 6 GND 7 CS0 SPI Chip Select 0 8 GND 9 CS1 SPI Chip Select 1 10 GND 11 CS2 SPI Chip Select 2 12 GND 13 CS3 SPI Chip Select 3 14 GND 15 CS4 SPI Chip Select 4 16 GND 17 Reserved Do Not Connect 18 Reserved Do Not Connect 19 Reserved Do Not Connect 20 Reserved Do Not Connect Table 3 2 I2C SPI Connector Pin Assignments Default ...

Страница 23: ...The PXIE 1149 1 4E unit is compatible with ScanExpress Runner ScanExpress Debugger and ScanExpress Programmer The following steps are provided for ScanExpress Runner Selecting the module in ScanExpress Debugger or ScanExpress Programmer is done in a similar fashion 1 Make sure that PXIE 1149 1 4E controller is installed into the PXI peripheral slot 2 Invoke the ScanExpress Runner application 3 Cli...

Страница 24: ...selections click on the Apply button to test and save the settings When the program saves the settings successfully it displays the controller in the Current Controller box If ScanExpress Runner cannot find the controller it displays an error dialog 6 Once ScanExpress Runner finds the PXIE 1149 1 4E controller it displays a screen similar to Figure 4 2 Figure 4 2 PXIE 1149 1 4E Setup Screen ...

Страница 25: ...t results and diagnostic messages in a log file if you have the ScanExpress Runner ADO and then terminate The following table shows the controller identifiers and associated parameters Consult the ScanExpress Runner User s Manual for more detail The PXIE 1149 1 4E controller uses 20 parameters The parameters are described in the table below Controller keyword USB 1149 1 4E Position Parameter Value...

Страница 26: ... in series for JTAG scanning Use TAPs 1 2 and 3 in series for JTAG scanning Use TAPs 1 2 3 and 4 in series for JTAG scanning 6 SPI I2C TAPs Default Configuration 1 2 3 4 5 Use None for direct programming Use TAP1 for direct programming Use TAP2 for direct programming Use TAP3 for direct programming Use TAP4 for direct programming 7 Delay Compensation 1 2 3 4 5 6 7 8 Automatic No Delay 0 5 Clock De...

Страница 27: ...5 V 3 30 V 11 TAP3 Voltage 1 2 41 42 1 25 V 1 30 V 0 05 V per step 3 25 V 3 30 V 12 TAP4 Voltage 1 2 41 42 1 25 V 1 30 V 0 05 V per step 3 25 V 3 30 V 13 TAP1 Input Threshold 1 2 3 31 32 Automatic 0 50 V 0 55 V 0 05 volts per step 1 95 V 2 00 V 14 TAP2 Input Threshold 1 2 3 31 32 Automatic 0 50 V 0 55 V 0 05 volts per step 1 95 V 2 00 V Table 5 1 PXIE 1149 1 4E Controller Parameters continued ...

Страница 28: ...nfigurations See the NOTE below 0xFDB97531 Custom pinout configuration 18 TA2 Pinout Configuration 0 324508639 355965919 4256789809 Standard pinout configuration 0x13579BDF Standard pinout configuration 0x15379BDF Custom pinout configuration Custom pinout configurations See the NOTE below 0xFDB97531 Custom pinout configuration 19 TA3 Pinout Configuration 0 324508639 355965919 4256789809 Standard p...

Страница 29: ...579BDF Standard pinout configuration 0x15379BDF Custom pinout configuration Custom pinout configurations See the NOTE below 0xFDB97531 Custom pinout configuration Table 5 1 PXIE 1149 1 4E Controller Parameters continued Example To select a PXIE 1149 1 4E controller card with all TAP voltages of 3 30 V automatic thresholds TCK frequency of 1 MHz automatic slew rate TAP1 for JTAG TAP2 for SPI automa...

Страница 30: ...2C SDA SCL For example the standard pinout configuration for JTAG is Signal Pin TRST 1 TDI 3 TDO 5 TMS 7 TCK 9 IO1 11 IO2 13 IO3 15 This would be represented as 0x13579BDF 324508639 in decimal format As another example the custom pinout configuration of Signal Pin TRST 1 TDI 5 TDO 7 TMS 9 TCK 3 IO1 11 IO2 13 IO3 15 would be represented as 0x15793BDF 360266719 in decimal format If an invalid number...

Страница 31: ...andard test equipment The UUT TAP contains 5 signals TCK TMS TDO TDI and optionally TRST It also contains ground signal s Corelis recommends the standard TAP connector shown in Figure A 1 which is widely regarded as the industry standard Note that each signal is terminated with a resistor discussed below in order to improve noise immunity The connector on the user s target should have a standard f...

Страница 32: ...K pull up 8 GND 9 TCK Input to the UUT 1K pull up 10 GND Table A 1 Signal Description and Termination Table A 2 summarizes the specifications for the 10 pin TAP connector Equivalent connectors are available from other manufacturers Reference Description Manufacturer Part Number 10 Pin Target TAP Straight header 10 pin 4 wall with center notch 3M 3473 6610 Table A 2 Standard 10 Pin TAP Connector No...

Страница 33: ...the corresponding interface voltage programmable on the PXIE 1149 1 4E from 1 25 to 3 3 V Recommended resistor values are 5 Figure A 2 TAP Connector Schematic Vcc Vcc Vcc Vcc 1K 33 1K 1K 1K TDI TMS TCK TDO 1 3 5 7 9 2 4 6 8 TAP Connector To all Boundary Scan Devices To TDI of 1st Device in the chain To all Boundary Scan Devices To all Boundary Scan Devices 10 Target Board TRST From TDO of last Dev...

Страница 34: ...2 Write_Strobe IO1 TDO TCK TMS TRST TDI Figure A 3 Boundary scan Flash Programming 16 Pin TAP Connector top view Corelis Flash Programming software supports the external signals Write_Strobe and Ready Busy in addition to the standard but slower scanned out in signals approach The Write_Strobe signal is active low and should be pulled up with a 1K resistor on the target board It needs to be logical...

Страница 35: ...put to the UUT 1K pull up or 1 5K pull down 2 GND 3 TDI Input to the UUT 1K pull up 4 GND 5 TDO Output from UUT 33 ohm series 6 GND 7 TMS Input to the UUT 1K pull up 8 GND 9 TCK Input to the UUT 1K pull up 10 GND 11 Write_Strobe Input to the UUT 1K pull up 12 GND 13 Reserved 14 GND 15 Ready Busy Output from UUT 1K pull up 16 GND Table A 4 Signal Description and Termination Note Some target boards ...

Страница 36: ...149 1 4E from 1 25 to 3 3 V Recommended resistor values are 5 Figure A 4 Flash Programming TAP Connector Schematics Vcc Vcc Vcc Vcc 1K 33 1K 1K 1K TRST TDI TMS TCK TDO 1 3 5 7 9 2 4 6 8 TAP Connector To all Boundary Scan Devices To TDI of 1st Device in the chain To all Boundary Scan Devices To all Boundary Scan Devices 10 Target Board 11 13 15 12 14 16 To flash device s WE control From flash Read ...

Страница 37: ...d Ready_Busy IO3 IO2 Write_Strobe IO1 TDO TCK TMS TRST TDI Figure A 5 Boundary scan Flash Programming 20 Pin TAP Connector top view Corelis Flash Programming software supports the external signals Write_Strobe and Ready Busy in addition to the standard but slower scanned out in signals approach The Write_Strobe signal is active low and should be pulled up with a 1K resistor on the target board It ...

Страница 38: ... GND 3 TDI Input to the UUT 1K pull up 4 GND 5 TDO Output from UUT 33 ohm series 6 GND 7 TMS Input to the UUT 1K pull up 8 GND 9 TCK Input to the UUT 1K pull up 10 GND 11 Write_Strobe GPIO1 Input to the UUT 1K pull up 12 GND 13 GPIO2 Input to the UUT 1K pull up 14 GND 15 Ready_Busy GPIO3 Output from the UUT 1K pull up 16 GND 17 reserved 18 reserved 19 reserved 20 reserved Table A 6 Signal Descript...

Страница 39: ... 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 TRST TDI TDO TMS TCK Write_Strobe GPIO1 Ready_Busy GPIO3 GPIO2 1K 1K 1K 1K 1K 1K 1K to all bounday scan devices to TDI of first device in the chain to all bounday scan devices to all bounday scan devices from TDO of last device in the chain Flash Ready Busy pin s Flash Write_Strobe pin s 33 The 33 ohm resistor should be placed physically clo...

Страница 40: ......

Страница 41: ...circumstances there is no need to run the self test utility software However if there is a possibility that the product is damaged un the self test on the PXIE 1149 1 4E module The self test utility can be found installed in the same folder where the ScanExpress Applications ScanExpress Runner ScanExpress Debugger and ScanExpress Programmer applications are also installed on your computer Make sur...

Отзывы: