Note the following, important notices regarding the use of Xesar wall readers.
Climatic and environmental effects
Note the defined suitability of the wall reader for the respective ambient conditions as per its IP
rating and specific temperature range.
Use the wall reader in environments with a humidity below 90% only.
Clarify the application options with a specialist retailer before installing wall readers in environ-
ments with a particularly high level of static charges.
Do not use wall readers in corrosive atmospheres (e.g. chlorine, ammonia, lime water or salt wa-
ter).
Information regarding installation and the correct installation situation
Exclusively specialist personnel must install wall readers and control units according to the specifi-
cations in the assembly manual which is also enclosed with the product. We particularly point out
to exclusively install the control unit when it is de-energised. EVVA shall assume no liability for any
kind for damage resulting from improper assembly/installation.
We recommend installing control units in tamper-proof areas.
Note that control unit operation requires a mains adapter. Said mains adapter is not within the
control unit's scope of delivery and optionally available as an accessory.
In the event that you are using a mains adapter you have not procured from EVVA, you must
make sure the power supply requirements illustrated in the product catalogue are complied with.
Wall readers and control units are exclusively intended to actuate electronic locking components
and technical equipment. The control unit is actuated using the relay outputs. The maximum per-
mitted switching performance of the relay outputs as per the product catalogue must be complied
with.
All Xesar access components are delivered ex works in so-called construction mode. In this condi-
tion any Construction Card unlocks any Xesar access component. For this reason, immediately
after having installed each Xesar access component ensure it is correctly added to the locking
system so that exclusively authorised persons have access.
Exclusively use accessories and spare parts recommended by EVVA.
Observe the corresponding international and national specifications in the corresponding legisla-
tion, directives, standards and guidelines, particularly regarding the requirements for escape routes
and emergency exits, during project management and installation of the control unit.