Ensure you selected the correct cylinder length for the corresponding door configuration. In instal-
lation situations or applications that are critical to security (without taking into account the thumb-
turn) the cylinder must protrude from the protective escutcheon by a maximum of 3 mm.
If VdS-certified mechatronic lock cylinders are installed in installation situations critical to security,
the lock cylinder must be protected by VdS-certified, burglary-resistent, category B or C door
plates. With regard to all other doors, the degree of anti-burglary measures must comply with the
corresponding, national regulations (see also EN 1627, Austrian standard 5338 or SKG).
Please note the restrictions illustrated in the assembly manual regarding the permissible installa-
tion positions of the lock cylinder. Non-compliance with the correct installation situation may
cause malfunctions – malfunctions in unapproved installation positions do not represent product
faults and are consequently not deemed as a valid reason for complaints. Please note that the
correct lock cylinder function can also only be ensured before and during installation of the lock
cylinder if the cylinder housing is positioned correctly.
Lock cylinders must be installed in such a way that they are not subject to any external forces
except when used correctly and at the designated mounting points.
A certificate in compliance with EN 179 or EN 1125 from the lock manufacturer is crucial for use
of the lock cylinder in escape or panic doors. Check the correct function of the complete panic
unit, consisting of lock cylinder, panic lock, panic bar and handle fittings. The aforementioned cer-
tificate must confirm the lock cylinders' suitability for installation.
Please note that if you would like to install the lock cylinder in smoke control/fire doors, you must
verify the cylinders' suitability and potentially also obtain approval from the door manufacturer.
The client shall be responsible for this.
An excessive tightening torque when fastening the cylinder fixing screw may cause lock cylinder
malfunctions or make it hard to operate the lock cylinder. For this reason, please note the data in
the assembly manual.
Before completing the installation, use a Construction Card to verify the correct function of the
lock cylinder when the door is open as per the specifications in the assembly manual.
After having installed the lock cylinder, note that you can only operate the system using a Con-
struction Card until parameters have been completely configured.