WT.025.000.001.UA.IM.0614
PAGE 5
CHLORINE HANDLING MANUAL
EVOQUA
W3T98244
Figure 2 – Manifolding Cylinders
3.2 MAXIMUM LIQUID WITHDRAWAL RATE
The generally accepted alternate to manifolding ton con-
tainers is to withdraw liquid chlorine from the lower valve
and use an evaporator. By this means, a ton container can
be emptied in approximately five hours, which is equivalent
to 9600 lbs/24 hrs.
Liquid can be withdrawn from tank cars at up to nearly 8,000
pounds per hour, or 192,000 pounds per 24 hours.
3.2.1
MANIFOLDING FOR LIQUID WITHDRAWAL
WARNING: IN ACCORDANCE WITH CHLORINE INSTI-
TUTE RECOMMENDATIONS, DO NOT MANIFOLD TON
CONTAINERS FOR SIMULTANEOUS LIQUID CHLORINE
WITHDRAWAL. THIS MANIFOLDING CAN CAUSE OVER-
PRESSURIZATION AND RUPTURE.
3.3 CONTAINER VALVES
Standard cylinder and ton container valves are identical in
design, except that the cylinder valve includes a pressure
relief device. Cylinder valves are shown in Figure 3 and ton
container valves in Figure 4.
See Figure 5 for captive yoke type auxiliary container valves
(valve connection style #820, recognized by the Compressed
Gas Association as the only acceptable means of connecting
to container valves). The external threads on the container
valve are used only for securing the protective cap.
Figure 3 – Standard Cylinder Valve
Figure 4 – Standard Ton Container Valve
Figure 5 – Auxiliary Ton Container Valve
Содержание V10K
Страница 1: ...V10K V NOTCH CHLORINATOR BOOK NO WT 025 100 001 UA IM 0614...
Страница 2: ...V10K V NOTCH CHLORINATOR BOOK NO WT 025 100 001 UA IM 0614 W3T109612...
Страница 12: ......
Страница 23: ......
Страница 45: ...WT 025 100 001 UA IM 0614 V10K V NOTCH CHLORINATOR 32 EVOQUA W3T109612...
Страница 46: ......
Страница 61: ......
Страница 90: ......
Страница 131: ......
Страница 133: ......
Страница 134: ...CHLORINE HANDLING MANUAL Cl2 BOOK NO WT 025 000 001 UA IM 0614 W3T98244...