The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control 
valve repairs or maintenance. The 1” full flow bypass valve incorporates four positions, including a diagnostic position that allows 
a service technician to have pressure to test a system while providing untreated bypass water to the building. Be sure to install 
bypass valve onto main control valve, before beginning plumbing. Or, make provisions in the plumbing system for a bypass. The 
bypass body and rotors are glass-filled Noryl

®

 and the nuts and caps are glass-filled polypropylene. All seals are self-lubricating 

EPDM to help prevent valve seizing after long periods of non-use. Internal “O” Rings can easily be replaced if service is required.

The bypass consists of two interchangeable plug valves that are operated independently by red arrow shaped handles. The 
handles identify the direction of flow. The plug valves enable the bypass valve to operate in four positions.

1.   

NORMAL OPERATION POSITION:

 The inlet and outlet handles point in the direction of flow indicated by the engraved 

arrows on the control valve. Water flows through the control valve for normal operation of a water softener. During 
the regeneration cycle this position provides regeneration water to the unit, while also providing untreated water to the 
distribution system 

(Fig. 1)

.

2.   

BYPASS POSITION:

 

The inlet and outlet handles point to the center of the bypass. The system is isolated from the water 

pressure in the plumbing system. Untreated water is supplied to the building 

(Fig. 2)

.

3.   

DIAGNOSTIC POSITION:

 The inlet handle points toward the control valve and the outlet handle points to the center of 

bypass valve. Untreated supply water is allowed to flow to the system and to the building, while not allowing water to exit 
from the system to the building (

Fig. 3)

. This allows the service technician to draw brine and perform other tests without the 

test water going to the building.

     

NOTE:

 The system must be rinsed before returning the bypass valve to the normal position.

4.   

SHUT OFF POSITION:

 The inlet handle points to the center of the bypass valve and the outlet handle points away from 

the control valve. The water is shut off to the building. The water treatment system will depressurize upon opening a tap in 
the building. A negative pressure in the building combined with the softener being in regeneration could cause a siphoning 
of brine into the building. If water is available on the outlet side of the softener, it is an indication of water bypassing the 
system 

(Fig. 4)

 (i.e. a plumbing cross-connection somewhere in the building).

 NORMAL 

OPERATION 

POSITION

 BYPASS POSITION

 DIAGNOSTIC 

POSITION

 SHUT OFF 

POSITION

FIGURE 1

FIGURE 3

FIGURE 2

FIGURE 4

 BYPASS VALVE:

Содержание EACG

Страница 1: ...Evolve Series Water Filters For Models EVFE EVS EAG EACG EVBF EVBF AN...

Страница 2: ...ase study this manual carefully and understand the cautions and notes before installing This manual should be kept for future reference If you have any questions regarding your water conditioner conta...

Страница 3: ...y Remaining and Days to a Regeneration are optional displays but are not normally used Vacation Mode is used only when there will be no water usage for an extended period of time If activated once 50...

Страница 4: ...regeneration water to the unit while also providing untreated water to the distribution system Fig 1 2 BYPASS POSITION The inlet and outlet handles point to the center of the bypass The system is iso...

Страница 5: ...een its outlet and the inlet of a water heater CAUTION To protect the unit in the event of a hot water heater backup the manufacturer recommends the use of an expansion tank on the outlet side of the...

Страница 6: ...control fitting and solder joints Failure to do this could cause interior damage to the flow control Backwash of an automatic filter can be directed into a septic tank in most cases but because of th...

Страница 7: ...neration which comes into contact with the chlorine pellets dissolves them and is then drawn into the filter to disinfect the system periodically and then safely rinsed away We recommend the use of pe...

Страница 8: ...alled for on that day even if a sufficient number of gallons were not used to call for a regeneration Set Day Override using or buttons 6 is recommended set number of days between regeneration 1 to 28...

Страница 9: ...r Press NEXT three times to advance past this screen STEP 7 SERVICE ALARM TIME The manufacturer has factory set OFF as the default This feature is used to signal service into the future This is typica...

Страница 10: ...hing and holding the REGEN button for three seconds while in the Backwash Air cycle will skip the remaining mini steps and proceed to the next cycle of regeneration which is usually Backwash The syste...

Страница 11: ...goes through a regeneration cycle based on the days override value 6 DEALER NAME AND PHONE NUMBER is the dealer information to call when service is needed this screen will only appear if set by dealer...

Страница 12: ...e based on gallons or time To turn off alarm If the audible alarm sounds press any button on the face of the control valve to turn off and call the dealer for service To reset Both the gallon alarm se...

Страница 13: ...Do not overfill The additional media added should not be higher than two thirds of the tank height when measuring from the bottom see diagram Once the right height has been achieved replace top fill p...

Страница 14: ...board C Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed...

Страница 15: ...in regenerant tank G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Contro...

Страница 16: ...r 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap...

Страница 17: ...on A Drive bracket not snapped in properly and out enough that reduction gears and drive gear do not interface A Snap drive bracket in properly then Press NEXT and REGEN buttons for 3 seconds to resyn...

Страница 18: ...power supply from PC board for 5 seconds and then reconnect 20 Err 109 A Invalid motor state detected A Replace PC board 21 Err 201 A Invalid regeneration cycle step detected A Replace PC board 22 Err...

Страница 19: ...acket spring clip 1 4 CV3502WE Evolve PC board used on chlorine generator models 1 CV4022WU Evolve PC board standard 1 5 CV3110 Drive gear 12 x 36 3 6 CV3109 Drive gear cover 1 7 CV3002CC Drive assemb...

Страница 20: ...assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 CV3358 O ring 219 1 25 distributor 8 CV3556 Screw 1 4 20x1 1 2 18 8SS...

Страница 21: ...Qty 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3145 Bypass rotor 1 2 5 CV3146 Bypass cap 2 6 CV3147 Bypass handle 2 7 CV3148 Bypass rotor seal retainer 2 8 CV3152 O...

Страница 22: ...or assembly YELLOW CV3010 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GREEN not shown CV3170 O ring 0...

Страница 23: ...CV3162 022 2 2 DLFC for 3 4 elbow CV3162 027 2 7 DLFC for 3 4 elbow CV3162 032 3 2 DLFC for 3 4 elbow CV3162 042 4 2 DLFC for 3 4 elbow CV3162 053 5 3 DLFC for 3 4 elbow CV3162 065 6 5 DLFC for 3 4 e...

Страница 24: ...1 Turbine assembly 1 4 CV3105 O ring 215 1 5 CV3003 01 Meter plug assembly 1 6 CV3013 Optional mixing valve 1 REPLACEMENT PARTS Although no tools are necessary to assemble or disassemble the valve the...

Страница 25: ...CHLORINE TANK ASSEMBLY Item No Part No Description Qty 1 CH4600 50 474 safety float valve 1 2 CH4640 32 474 float assembly 1 3 CH4500 48 474 air check 1 4 CN1043 10 pad for feeder 1 5 CH7001 Grid for...

Страница 26: ...Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connect 2...

Страница 27: ...Bite assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assem...

Страница 28: ...Plus Calcite Greensand Plus Calcite Greensand Plus Calcite 1 Amount Cu Ft 1 0 1 5 2 0 1 0 1 5 2 0 Gravel Amount Size No 1 14 lb 1 4 x 1 8 21 lb 1 4 x 1 8 21 lb 1 4 x 1 8 14 lb 1 4 x 1 8 21 lb 1 4 x 1...

Страница 29: ...1 8 14 lb 1 4 x 1 8 21 lb 1 4 x 1 8 Gravel Amount Size No 2 7 lb 20 7 lb 20 7 lb 20 7 lb 20 7 lb 20 7 lb 20 Continuous Flow GPM 5 0 5 0 6 0 6 0 7 0 11 0 Peak Flow GPM 8 0 9 0 12 0 10 0 11 0 18 0 Back...

Страница 30: ...expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent manner and conditio...

Страница 31: ...water REGEN TODAY MON GPM 2 40 8 PM REGEN TODAY and TIME OF DAY will flash alternately if a regeneration is expected tonight NORMAL OPERATION BYPASS OPERATION QUICK REFERENCE GUIDE GENERAL OPERATION...

Страница 32: ...ress NEXT 8 Adjust time of regeneration minutes with and buttons 9 Press NEXT 10 Turn service alarm time ON with and buttons Default is OFF 11 Press NEXT twice 12 Turn service alarm gallons ON with an...

Отзывы: