Evolve EACG Скачать руководство пользователя страница 15

15

 7.   Control valve does not 

regenerate automatically 
but 

does

 when the 

correct button(s) is 
depressed and held. 
For timeclock valves the 
buttons are 

▲ 

For all other valves the 
button is REGEN.

 A. Bypass valve in bypass position

 A.  Turn bypass handles to place bypass in 

service position

 B.  Meter is not connected to meter connection on 

PC board

 B.  Connect meter to three pin connection labeled 

METER on PC board

 C. Restricted/stalled meter turbine

 C.  Remove meter and check for rotation or 

foreign material

 D. Incorrect programming

 D. Check for programming error

 E.  Meter wire not installed securely into three 

pin connector

 E.  Verify meter cable wires are installed securely 

into three pin connector labeled METER

 F. Defective meter

 F. Replace meter

 G. Defective PC board

 G. Replace PC board

 8.   Hard or untreated 

water is being 
delivered

 A. Bypass valve is open or faulty

 A. Fully close bypass valve or replace

 B. Media is exhausted due to high water usage

 B.  Check program settings or diagnostics for 

abnormal water usage

 C. Meter not registering

 C.  Remove meter and check for rotation or 

foreign material

 D. Water quality fluctuation

 D.  Test water and adjust program 

values accordingly

 E.  No regenerant or low level of regenerant in 

regenerant tank

 E. Add proper regenerant to tank

 F. Control fails to draw in regenerant

 F. Refer to Troubleshooting Guide number 12

 G. Insufficient regenerant level in regenerant tank

 G.  Check refill setting in programming. Check 

refill flow control for restrictions or debris and 
clean or replace

 H. Damaged seal/stack assembly

 H. Replace seal/stack assembly

 I.  Control valve body type and piston type 

mix matched

 I.  Verify proper control valve body type and  

piston type match

 J. Fouled media bed

 J. Replace media bed

 9.   Control valve uses too 

much regenerant

 A. Improper refill setting

 A. Check refill setting

 B.  Improper program settings

 B.  Check program setting to make sure 

they are specific to the water quality and 
application needs

 C. Control valve regenerates frequently

 C.  Check for leaking fixtures that may be 

exhausting capacity or system is undersized

 10.   Residual regenerant 

being delivered to 
service

 A. Low water pressure

 A.  Check incoming water pressure – water 

pressure must remain at minimum of 25 psi

 B. Incorrect injector size

 B.   Replace injector with correct size for 

the application

 C.  Restricted drain line

 C.  Check drain line for restrictions or debris 

and clean

 11.   Excessive water in 

regenerant tank

 A.  Improper program settings

 A. Check refill setting

 B. Plugged injector

 B. Remove injector and clean or replace

 C. Drive cap assembly not tightened in properly

 C. Retighten the drive cap assembly

 D. Damaged seal/stack assembly

 D. Replace seal/stack

 E. Restricted or kinked drain line

 E.  Check drain line for restrictions or debris and 

or unkink drain line

 F. Plugged backwash flow controller

 F.  Remove backwash flow controller and clean 

or replace

 G. Missing refill flow controller

 G. Replace refill flow controller

 PROBLEM 

CAUSE 

CORRECTION 

Содержание EACG

Страница 1: ...Evolve Series Water Filters For Models EVFE EVS EAG EACG EVBF EVBF AN...

Страница 2: ...ase study this manual carefully and understand the cautions and notes before installing This manual should be kept for future reference If you have any questions regarding your water conditioner conta...

Страница 3: ...y Remaining and Days to a Regeneration are optional displays but are not normally used Vacation Mode is used only when there will be no water usage for an extended period of time If activated once 50...

Страница 4: ...regeneration water to the unit while also providing untreated water to the distribution system Fig 1 2 BYPASS POSITION The inlet and outlet handles point to the center of the bypass The system is iso...

Страница 5: ...een its outlet and the inlet of a water heater CAUTION To protect the unit in the event of a hot water heater backup the manufacturer recommends the use of an expansion tank on the outlet side of the...

Страница 6: ...control fitting and solder joints Failure to do this could cause interior damage to the flow control Backwash of an automatic filter can be directed into a septic tank in most cases but because of th...

Страница 7: ...neration which comes into contact with the chlorine pellets dissolves them and is then drawn into the filter to disinfect the system periodically and then safely rinsed away We recommend the use of pe...

Страница 8: ...alled for on that day even if a sufficient number of gallons were not used to call for a regeneration Set Day Override using or buttons 6 is recommended set number of days between regeneration 1 to 28...

Страница 9: ...r Press NEXT three times to advance past this screen STEP 7 SERVICE ALARM TIME The manufacturer has factory set OFF as the default This feature is used to signal service into the future This is typica...

Страница 10: ...hing and holding the REGEN button for three seconds while in the Backwash Air cycle will skip the remaining mini steps and proceed to the next cycle of regeneration which is usually Backwash The syste...

Страница 11: ...goes through a regeneration cycle based on the days override value 6 DEALER NAME AND PHONE NUMBER is the dealer information to call when service is needed this screen will only appear if set by dealer...

Страница 12: ...e based on gallons or time To turn off alarm If the audible alarm sounds press any button on the face of the control valve to turn off and call the dealer for service To reset Both the gallon alarm se...

Страница 13: ...Do not overfill The additional media added should not be higher than two thirds of the tank height when measuring from the bottom see diagram Once the right height has been achieved replace top fill p...

Страница 14: ...board C Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed...

Страница 15: ...in regenerant tank G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Contro...

Страница 16: ...r 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap...

Страница 17: ...on A Drive bracket not snapped in properly and out enough that reduction gears and drive gear do not interface A Snap drive bracket in properly then Press NEXT and REGEN buttons for 3 seconds to resyn...

Страница 18: ...power supply from PC board for 5 seconds and then reconnect 20 Err 109 A Invalid motor state detected A Replace PC board 21 Err 201 A Invalid regeneration cycle step detected A Replace PC board 22 Err...

Страница 19: ...acket spring clip 1 4 CV3502WE Evolve PC board used on chlorine generator models 1 CV4022WU Evolve PC board standard 1 5 CV3110 Drive gear 12 x 36 3 6 CV3109 Drive gear cover 1 7 CV3002CC Drive assemb...

Страница 20: ...assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 CV3358 O ring 219 1 25 distributor 8 CV3556 Screw 1 4 20x1 1 2 18 8SS...

Страница 21: ...Qty 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3145 Bypass rotor 1 2 5 CV3146 Bypass cap 2 6 CV3147 Bypass handle 2 7 CV3148 Bypass rotor seal retainer 2 8 CV3152 O...

Страница 22: ...or assembly YELLOW CV3010 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GREEN not shown CV3170 O ring 0...

Страница 23: ...CV3162 022 2 2 DLFC for 3 4 elbow CV3162 027 2 7 DLFC for 3 4 elbow CV3162 032 3 2 DLFC for 3 4 elbow CV3162 042 4 2 DLFC for 3 4 elbow CV3162 053 5 3 DLFC for 3 4 elbow CV3162 065 6 5 DLFC for 3 4 e...

Страница 24: ...1 Turbine assembly 1 4 CV3105 O ring 215 1 5 CV3003 01 Meter plug assembly 1 6 CV3013 Optional mixing valve 1 REPLACEMENT PARTS Although no tools are necessary to assemble or disassemble the valve the...

Страница 25: ...CHLORINE TANK ASSEMBLY Item No Part No Description Qty 1 CH4600 50 474 safety float valve 1 2 CH4640 32 474 float assembly 1 3 CH4500 48 474 air check 1 4 CN1043 10 pad for feeder 1 5 CH7001 Grid for...

Страница 26: ...Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connect 2...

Страница 27: ...Bite assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assem...

Страница 28: ...Plus Calcite Greensand Plus Calcite Greensand Plus Calcite 1 Amount Cu Ft 1 0 1 5 2 0 1 0 1 5 2 0 Gravel Amount Size No 1 14 lb 1 4 x 1 8 21 lb 1 4 x 1 8 21 lb 1 4 x 1 8 14 lb 1 4 x 1 8 21 lb 1 4 x 1...

Страница 29: ...1 8 14 lb 1 4 x 1 8 21 lb 1 4 x 1 8 Gravel Amount Size No 2 7 lb 20 7 lb 20 7 lb 20 7 lb 20 7 lb 20 7 lb 20 Continuous Flow GPM 5 0 5 0 6 0 6 0 7 0 11 0 Peak Flow GPM 8 0 9 0 12 0 10 0 11 0 18 0 Back...

Страница 30: ...expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent manner and conditio...

Страница 31: ...water REGEN TODAY MON GPM 2 40 8 PM REGEN TODAY and TIME OF DAY will flash alternately if a regeneration is expected tonight NORMAL OPERATION BYPASS OPERATION QUICK REFERENCE GUIDE GENERAL OPERATION...

Страница 32: ...ress NEXT 8 Adjust time of regeneration minutes with and buttons 9 Press NEXT 10 Turn service alarm time ON with and buttons Default is OFF 11 Press NEXT twice 12 Turn service alarm gallons ON with an...

Отзывы: