PREINSTALLATION INSTRUCTIONS FOR DEALERS:
3
The manufacturer has preset the water treatment unit’s sequence of cycles and cycle times.
The dealer
should read this page and guide the installer regarding day override, time of regeneration, service alarm
and buzzer alarm settings before installation.
For the installer
, the following must be used:
•
Program Installer Settings ... Day Override (preset to 3 days), Time of Regeneration (preset to 12:00 a.m.;
see Operating Displays and Instructions for more details), Service Alarms (preset to “OFF”) and Buzzer Alarm
(preset to start at 6 a.m. and end at 10 p.m.)
• Read Normal Operating Displays
• Set Time of Day
• Read Power Loss & Error Display
For the homeowner
, please read sections on Bypass Valve and Operating Displays and Maintenance.
During operation, the normal user display is
time of day
and
gallons per minute
.
Flow Rate, Vacation Mode, Capacity Remaining and Days to a Regeneration
are optional displays but are not normally
used. (Vacation Mode is used only when there will be no water usage for an extended period of time. If activated, once
50 gallons of water is used, the unit will automatically regenerate that night and resume normal operation.) Each of these
can be viewed by pressing
NEXT
to scroll through them. When stepping through any programming, if no buttons are
pressed within 5 minutes, the display returns to a normal user display. Any changes made prior to the 5 minute time out
are incorporated. To quickly exit any Programming, Installer Settings, etc., press
SET
CLOCK
. Any changes made prior to
the exit are incorporated.
If desired, two regenerations within 24 hours are possible with a return to the preset program.
To do a
double regeneration
:
1. Press the
REGEN
button once. “REGEN TODAY” will flash on the display.
2. Press and hold the
REGEN
button for three seconds until a regeneration begins.
Once the valve has completed the immediate regeneration, the valve will regenerate one more time at the preset.