background image

 

 

21 

 

F23 

Machine type 

0:Heating & Cooling 
1:Heating ONLY 
2:Cooling ONLY 

F24 

Constant temp. superheat 

-5~10

℃(

-10~20

℉)

 

According to the actual model 

F25 

Frequency set_11 

20~120Hz 

70 Hz 

F26 

Frequency set_12 

20~120Hz 

74 Hz 

F27 

Frequency set_13 

20~120Hz 

78 Hz 

F28 

Frequency set_14 

20~120Hz 

82 Hz 

F29 

Frequency set_15 

20~120Hz 

84 Hz 

F30 

Frequency set_16 

20~120Hz 

86 Hz 

F31 

Frequency set_17 

20~120Hz 

88 Hz 

F32 

Frequency set_18 

20~120Hz 

90 Hz 

 

 

  Timer Setting.

 

 

8)  Date and Clock Setting. 

 

  In the clock setting interface, click "

" to confirm the time settings. 

Содержание evotherm EFI Ultra V30T

Страница 1: ...echnician Improper installation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty This manual contains important information about the installation operation and safe use of this product Once the product has been installed this manual must be given to the owner operator of this equipment ...

Страница 2: ...ONNECTION 9 3 1 Notice Before Installation 10 3 2 Installation Instruction 10 3 2 1 Pre requirements 10 3 2 2 Heat Pump Installation 10 3 2 3 Location and Space 11 3 2 4 Installation Layout 11 3 3 5 Electrical Installation 14 3 3 6 Electrical Connection 14 3 3 Trial After Installation 16 3 4 1 Inspection Before Trial Running 16 3 4 2 Trial Running 16 4 REMOTE CONTROLLER OPERATION GUIDANCE 17 4 1 C...

Страница 3: ...USER INSTRUCTION 26 5 1 Wi Fi Box 26 5 2 Wi Fi Function 27 5 2 1 Software Installation 27 5 2 2 Software Startup 27 5 2 3 Software Registration and Configuration 28 5 2 4 Software Function Operation 36 5 2 5 Device Removal 41 6 MAINTENANCE AND WINTERZING 43 6 1 Maintenance 43 6 2 Winterizing 43 ...

Страница 4: ...The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flammable atmospheres Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants i e non sparking adequately sealed or intrinsically safe Presence of fire extinguisher If any hot work is to be conducted on the refriger...

Страница 5: ...rking on electrical components the casing is not altered in such a way that the level of protection is affected This shall include damage to cables excessive number of connections terminals not made to original specification damage to seals incorrect fitting of glands etc Ensure that the apparatus is mounted securely Ensure that seals or sealing materials have not degraded to the point that they n...

Страница 6: ... not be used for this task Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved then venting to atmosphere and finally pulling down to a vacuum This process shall be repeated until no refrigerant is within the system When the final OFN charge is used the system shall be vented down to atmospheric pressure to enable w...

Страница 7: ...nly appropriate refrigerant recovery cylinders are employed Ensure that the correct number of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labeled for that refrigerant i e special cylinders for the recovery of refrigerant Cylinders shall be complete with pressure relief valve and associated shut off valves in ...

Страница 8: ... Wrong operation may result in injury or damage Please install the unit in compliance with local laws regulations and standards Confirm power voltage and frequency The unit is only used with grounding sockets Independent switch must be offered with the unit 1 4 Safety Factors The following safety factors need to be considered Please read the following warnings before installation Be sure to check ...

Страница 9: ...it will cause explosion According to the instruction to carry out drainage system and pipeline work If drainage system or pipeline is defective water leakage will occur And it should be disposed immediately to prevent other household products from getting wet and damage Do not clean the unit while power is on Turn off power before cleaning the unit If not it may result in injury from a high speed ...

Страница 10: ... check if you have all the following components NO Components Quantity NO Components Quantity User Manual 1 Drain Pipe 1 Rubber Blanket 4 Water Pipe Joint 2 Drain Connector 1 2 2 Dimensions of the Unit Dimension Unit mm A B C D E F G H I EFI Ultra V30T 900 812 1054 865 846 500 252 145 268 ...

Страница 11: ... 4 Top cover plate 13 Fin heat exchanger 22 Fixed plate 5 Metal mesh cover 14 Four way valve welding assembly 23 Globe valve 6 Stand column 1 15 Titanium tube heat exchanger 24 Drive board 7 Damper 16 Gas liquid separator 25 Filter welding components 8 Electrical box 1 17 Inverter compressor 26 Chassis components 9 Electrical box 2 18 Stand column 3 27 Inlet piping components ...

Страница 12: ...ure range Heating 15 40 Setting temperature range Cooling 8 28 Running temperature range 10 43 Refrigerant R32 Compressor MITSUBISHI ELECTRIC DC inverter Air side heat exchanger Hydrophilic fin and tube Water side heat exchanger Titanium PVC Tank Water flow LPM 190 Net dimension LxWxH mm 900x812x1054 Water pipe connection mm 40 50 Net weight kg 137 Noise level dB A 46 68 Water proof level IPX4 3 I...

Страница 13: ...unit to your installation by means of flexible PVC pipes in order to reduce the transmission of vibrations Suitable fastening studs may be used to raise the unit 3 2 2 Heat Pump Installation The frame must be fixed by bolts M10 to concrete foundation or brackets The concrete foundation must be solid the bracket must be strong enough and anti rust treated The heat pump needs a water pump Supplied b...

Страница 14: ...o oil flammable gases corrosive products sulphur compounds or close to high frequency equipment To prevent mud splashes do not install the unit near a road or track To avoid causing nuisance to neighbors make sure the unit is installed so that it is positioned towards the area that is least sensitive to noise Keep the unit as much as possible out of the reach of children Installation space Unit mm...

Страница 15: ...rged air will not be breathed in To perfect your installation Avoid directing the flow of ventilated air towards a sensitive noise zone such as room window Avoid positioning pool heat pump on a surface that can transmit vibrations to dwelling Try to avoid placing appliance under a tree or exposed to water or mud which would be likely to complicate maintenance Water connection Water connection the ...

Страница 16: ...13 ...

Страница 17: ...ble must be suitable for outdoor use For a three phase system it is essential to connect the phases in the correct sequence If the phases are inverted the heat pump s compressor will not work In places open to the public it is mandatory to install an emergency stop button close to the heat pump Model Power Supply Wires Electricity Supply Cable Diameter Specification EFI Ultra V30T 380 415V 3N 50Hz...

Страница 18: ...15 ...

Страница 19: ...ectly 3 4 2 Trial Running Step 1 Running test can begin after completing all installation Step 2 All wiring and piping should be connected well and carefully checked then fill water tank with water before power is switched on Step 3 Emptying all air within pipes and water tank press on off button on control panel to run the unit at setting temperature Step 4 Items need to be checked during running...

Страница 20: ...imer Defrosting Set Temp Target Temperature Water Temp Current Temperature 4 3 Key Operating Instruction 1 On Off Key Click On Off key on the main interface to turn on or off the unit Click On Off key on the other interface to return directly to the main interface 2 Up Key and Down Key In the main interface click to modify the setting temperature ...

Страница 21: ...n the parameter checking interface click and to turn the page up or down 5 On Off Key Click On Off key on the main interface to turn on or off the unit 6 Mode Key Click on the main interface to switch between cooling and heating modes 7 Query Key Click on the main interface to enter main menu Machine status Click it to enter the unit state parameter query ...

Страница 22: ... Adjustment Range Initial Value 1 Return temp difference 1 18 2 36 1 2 2 Cooling set temp 8 35 46 95 27 81 3 Heating set temp 5 40 41 104 27 81 4 Temp compensation 5 15 10 30 0 0 5 Def cycle 20min 90min 45min 6 Def start temp 9 1 16 30 3 27 7 Def max time 5min 20min 8min 8 Def exit temp 1 40 33 104 15 68 9 Def ambient and coil T 0 15 0 30 5 10 10 Def ambient temp 0 20 32 68 17 63 11 EEV working cy...

Страница 23: ..._1 20 120Hz 20 Hz F2 Frequency set_2 20 120Hz 24 Hz F3 Frequency set_3 20 120Hz 28 Hz F4 Frequency set_4 20 120Hz 32 Hz F5 Frequency set_5 20 120Hz 36 Hz F6 Frequency set_6 20 120Hz 40 Hz F7 Frequency set_7 20 120Hz 44 Hz F8 Frequency set_8 20 120Hz 46 Hz F9 Frequency set_9 20 120Hz 58 Hz F10 Frequency set_10 20 120Hz 68 Hz F11 Exhaust temp set_1 50 125 122 257 95 203 F12 Exhaust temp set_2 50 125...

Страница 24: ...0Hz 70 Hz F26 Frequency set_12 20 120Hz 74 Hz F27 Frequency set_13 20 120Hz 78 Hz F28 Frequency set_14 20 120Hz 82 Hz F29 Frequency set_15 20 120Hz 84 Hz F30 Frequency set_16 20 120Hz 86 Hz F31 Frequency set_17 20 120Hz 88 Hz F32 Frequency set_18 20 120Hz 90 Hz Timer Setting 8 Date and Clock Setting In the clock setting interface click to confirm the time settings ...

Страница 25: ...re sensor failure Er 18 Exhaust temperature sensor failure Er 20 Inverter module abnormal protection Er 21 Ambient temperature sensor failure Er 23 Outlet water low temp Protection Er 27 Water outlet temperature sensor failure Er 28 CT over current protection Er 29 Water inlet temperature sensor failure Er 32 Outlet Water Over Heat Protection Er 33 Heating Coil Over Heat Protection Er 42 Internal ...

Страница 26: ...l 1 Check whether the communication cable is improperly connected 2 Check whether the baud rate and communication address code are set according to the communication protocol 3 Replace the driving board for testing 258 AC phase loss or CT is disconnected 1 The current transformer on the driving board is damaged during transportation 2 Check whether the current transformer is improperly inserted du...

Страница 27: ...oller shows no display No power supply Check whether cable and circuit breaker are connected Wire controller displays the actual time Heat pump under standby status Start up heat pump to run Wire controller displays the actual water temperature 1 Water temperature is reaching set value heat pump under constant temperature status 2 Heat pump just starts to run 3 Under defrosting 1 Verify water temp...

Страница 28: ...e location of the heat pump and eliminate all obstacles to assure a good air ventilation 3 Replace or repair the heat pump water stains Water stains on heat pump unit 1 Condensed water 2 Water leakage 1 No action 2 Check the titanium heat exchanger carefully if it shows any defects Too much ice on evaporator Too much ice on evaporator 1 Check the location of heat pump and eliminate all obstacles t...

Страница 29: ... to enter AP mode 2 Power indicator When power is on the lower indicator lights up 3 Wi Fi connection indicator After Wi Fi is connected the lower indicator light is always on 4 Communication indicator 1 when entering EZ mode the lower indicator flashes quickly 2 When entering AP mode the lower indicator slowly 3 After the distribution network connection is successful the lower indicator represent...

Страница 30: ...n 5 2 1 Software Installation Method 1 Search Smart life in your APP store install Click GET to install Method 2 Scan the QR code below 5 2 2 Software Startup After installation click on your desktop to start up Smart Life ...

Страница 31: ...ation Users don t have account can click Register to create an account Register Enter your phone number Get Verification Code Enter Verification Code Set Code After registration you need to create a Home Create a Home Set Home Name Set Home Location Add Rooms ...

Страница 32: ...29 2 Account ID Password Login Existing accounts can be logged in directly in the following order ...

Страница 33: ...forget your password you can choose to login with your verification code and select Forget Password Enter your phone number Get verification code After creating a home or logged in enter the main interface of APP ...

Страница 34: ... it Manually enter the EZ mode 10s after power on long press on for 3s to enter EZ mode the the indicator light under flashes rapidly 2 times per second mobile phone can connect it Step 2 Turn on the phone s Wi Fi function and connect to the Wi Fi hot spot The Wi Fi hot spot must be able to connect to the Internet normally Step 3 Open the smart life APP log in into the main interface click on the ...

Страница 35: ... has selected the EZ mode After the indicator light under flashes rapidly click Confirm indicator rapidly blink Enter the Wi Fi connection interface enter the Wi Fi password of the mobile phone it must be the same as the Wi Fi of the mobile phone click Next and then directly enter the connected status of the device ...

Страница 36: ...33 Step 5 When Scan devices Register on Cloud Initialize the device are all completed connect succeeds ...

Страница 37: ...tering the add device interface click EZ Mode in the upper right corner Enter the AP mode to add the device interface confirm that the AP mode has been selected icon flashes and click Confirm indicator slowly blink The interface of Wi Fi connection will pop up enter the Wi Fi password of the mobile phone it must be the same as the Wi Fi of the mobile phone click Next Connect your mobile phone to t...

Страница 38: ...35 Enter the mobile phone Wi Fi connection interface find the Smart Life_XXXX connection and the APP will automatically enter the device connection status ...

Страница 39: ...terface Back More You can change device name select device installation location check networking status add Shared users create device cluster view device information and more Setting temperature adjustment The white circle slides counterclockwise to reduce the temperature but clockwise to increase the temperature Target temperature Current temperature Mode switching Click to select the mode to b...

Страница 40: ...user should do so in the following order After successful sharing the list will be added to show the person shared If you want to delete the account you shared to cross the selected account to the left and delete it The user interface is as follows ...

Страница 41: ...e shared click Done and the share success list shows the newly added account of the Shared The interface of the person to be shared is as follows The received shared device is displayed Click it to operate and control the device ...

Страница 42: ...39 Mode settings Click on the main interface to switch modes select what you need Timer setting ...

Страница 43: ...main interface to enter timer setting interface as shown below click to add timer 2 After entering timer setting swipe up down to set timer set up repeat weeks and on off then click save to save your settings as follows ...

Страница 44: ...ashes rapidly for 3min the network can be re matched or quit it if no operation within 3 minutes 2 By APP Click on the top right corner of the main interface to enter the device details interface and click device removal to enter EZ mode Indicator light under flashes rapidly for 3min the network can be reconfigured within 3 minutes and the network can be quit if it is not connected within 3 minute...

Страница 45: ...42 ...

Страница 46: ...e following operations must be undertaken by a qualified person at least once a year a Carry out safety checks b Check the integrity of the electrical wiring c Check the earthing connections d Monitor the state of the pressure gauge and the presence of refrigerant 6 2 Winterizing In winter season when you don t swim a Cut off power supply to prevent any machine damage b Drain water clear of the ma...

Страница 47: ......

Страница 48: ......

Отзывы: