3
4.0
POWER PACK INSTALLATION
4.1
The Evochlor Wireless Chlorinator power pack is wall mounted using the supplied
mounting bracket or directly hanging on the wall with screws (300mm centres). The
power pack must be mounted at least 1 metre above the ground and 3 metres or more
from the pool edge.
4.2
It is strongly recommended that the power pack be installed where it is protected
from the elements. Rain and sunlight will prematurely age the unit. It should also be
mounted in a position where it is away from accidental water spray. The power pack
should be installed so that adequate airflow can circulate freely around the unit to
allow for sufficient ventilation.
4.3
The power pack comes with a standard 230V 10A power cable that is to be connected to
mains power. Plug the power cable into a suitable weatherproof outlet.
4.4
The power pack is fitted with a 230V 10A power socket located on the right-hand
underside of the power pack. The pool pump should be plugged into this socket so
that the chlorinator and pump activate together when the timer switches on at the
allocated time settings. Failure to plug the pool pump into this socket could lead to the
chlorinator staying on with no water circulation. Without circulation, and in the event of
a water probe failure, overheating and a possible gas build-up may occur. This build-up
may damage the cell housing.
4.5
The electrolytic cell cable is connected to the power pack at the junction box on the
underside of the unit. With power off, remove the protective cover from the junction
box and insert the cell cable wires to the terminals, with the thin wire connecting to the
middle position. The screws must be firmly tightened so there is solid contact between
the wires and the terminals. Replace the protective cover back over the junction box.
Содержание evochlor A20BT
Страница 19: ...17 12 0 NOTES...