7
5.3
UA PROTECTION AND THE BULB EXPLOSION
Prohibit straight viewpoint with exposed bulbs to avoid UV damage to the eyes;
Do not use the equipment without the lens screen and the lid;
The lens and the light head covers should be timely replaced if any damage to rupture
The Fixture should be used with the protection screen together.
5.4.1
ANTI-HIGH TEMPERATURE
(Rated maximum ambient temperature)
t
a
=40°C
Please don’t use the equipment if the temperature above 40℃.
5.4.2
ANTI-HIGH TEMPERATURE (Maximum outer surface temperature)
t
c
=110°C
When the luminaire reaches the state of thermal stability, the maximum temperature on the
external surface can reach 110 degrees. Please do not touch the lamp body when the luminaire is
working.
5.5
IP PROTECTION
The product are certified at IP 20 levels only. Adequate additional protection should be taken
for outdoor use. All lamps, lights and their fittings should be kept dry. Overheating dust and
excessive humidity must be avoided.
5.6
BURST PREVENTION
1. The lens should be changed if had damaged or any problems.
2. Don’t change the non-original manufacturer len
3. Len size
:¢
160*57.5mm
。
5.7
PREVENTION OF ELECTIC SHOCK
1.The electrical connection must only be carried out with corresponding qualifications;
2.Before installing, make sure you use the power voltage lamps must comply with the
identified power, voltage and have an overload or leakage protection;
3.Each lamp must be properly grounded, installed in accordance with the relevant standards;
4.Cut off the power when stall or replace the lamp and the fuse;
5.Prohibit the use of a lightning storm or wet environment.