10
twisted pair cable; standard loudspeaker cable is not reliable to control the long-range data.
24AWG cable is suitable for more than 300 meters long-distance signal transmission and must
add\ DMX 512 signal amplifier.
Do not use two outputs to separate the connection, if separate a continuous connection to branch,
DMX512 splitter is necessary.
If use the DMX512 splitter. At first connect DMX512 Splitter input terminal to controller .And
then connected from the splitter output terminal to next device.
Do as above guide to connect other device, and finally coupled with terminal insertion
8.AC POWER
8.1
VOLTAGE, POWER, FUSE SPECIFICATION
Input Voltage
Total Power
Frequency
110-240V
540W
50/60HZ
Fuse voltage
Electronic current
Specification
250V
10A
5×20
8.2
Power connection attention
Attention!
The device must be operated by professionals; Make sure that the voltage of power supply must be
comply with the voltage identified on the lamp, and must have an overload or leakage electrical
protection.
Attention
!
The factory has been equipped with standard 3-pin plug and socket, which is connected to the
power supply correctly according to the signs listed in the table, yellow / green If the flexible cord
of the lamp is damaged, it should be replaced by the factory or its service agent or qualified
personnel. If you have any questions about installation, you can consult with a qualified lectrician.
Live wire(L)
Null(N)
Ground wire
Brown
BLUE
Green
9. LAMP MODEL AND REPLACE
9.1
LAMP
LAMP MODEL
POWER
Life / hour
OSRAM SIRIUS HRI 382W
382W
1500 hours
Содержание HYBRID 18R