background image

2

3

            Remember that some fundamental safety rules should be followed when using this product:
            1. This appliance is not intended for use by persons(including children) with reduced physical, 
                sensory or mental capabilities, or lack of experience and knowledge, unless they have been
                given supervision or instruction concerning use of the appliance by a person responsible for
                their safety. Children should be supervised to ensure that they do not play with the appliance.
            2. It is forbidden to touch the appliance with wet hands or body when barefoot.
            3. It is forbidden to carry out any cleaning before having disconnected the appliances from the 
                 electricity mains supply by turning the system master switch to OFF.
            4. It is forbidden to modify the safety or adjustment devices or adjust without authorization and 
                 indication of the manufacturer.
            5. It is forbidden to pull, cut or knot the electrical cables coming out of the appliance, even if it is 
                 disconnected from the mains supply. 
            6. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or 
                 similarly qualified persons in order to avoid a hazard.
            7. It is forbidden to poke objects or anything else through the inlet or outlet grills.
            8. It is forbidden to dispose of or leave in the reach of children the packaging materials which 
                 could become a source of danger.
            9. It is forbidden to climb onto the appliance or rest any object on it.
           10. It is forbidden to touch the unit with hands directly as the external parts of the appliance can 
                  reach temperatures of more than 70

.

           11. The appliance shall be installed in accordance with national wiring regulations.

INSTALLATION

Fix the unit

Need circuit breaker

Make sure that there is circuit breaker for the unit. Lack of 
circuit breaker can lead to electrical shock or fire.

Prohibit

Please use the suitable fuse.
If copper or icon is used to replace the fuse, it will cause 
failure, even fire.

Ö  Ì  µ  °  ×

OPERATION

Check the installation

basement

Disconnect the power

Please check the installation basement regularly to avoid
any decline or damage which may hurt people or damage 
the unit.

Please disconnect the power to the unit for clean or 
maintenance.

Make sure that the basement of the unit is strong enough 
to avoid any decline or fall down.

Meaning

Meaning

2.4 Attention

Mark

Meaning

A wrong operation may lead to death or heavy injury on people. 

A wrong operation may lead to harm to people or loss of property. 

WARNING

 ATTENTION

Entrust a specialized personnel for installation. Wrong installation 
may cause leakage, personnel electric shock or fires.

Confirm whether wether the unit is with correct earthing. Wrong 
connection may cause personnel shock.

IN

S

T

A

L

L

A

T

IO

N

PROFESSIONAL 

INSTALLER IS REQUIRED

EARTHING 

IS REQUIRED

Icon

Meaning

Prohibition. What is prohibited will be nearby this icon.

Compulsory implement. The listed actions need to be taken.

Attention(include warnings)
Please pay attention to what is indicated.

Do not put fingers or others into the fan or  evaporator of the unit, 
otherwise harm may be occurred.

O

P

E

R

A

T

IO

N

PROHIBITION

SHUT OFF 

THE POWER

When the unit needs to be moved or installed again, please entrust
dealer or qualified person to carry it out. Improper installation may lead to 
water leakage, electrical shock, injury or fire.

It is prohibited to repair the unit by the user himself, otherwise electrical 
shock or fire may occur.

When the unit needs to be repaired, please entrust dealer or qualified 
person to carry it out. Improper movement or repair on the unit may lead to 
water leakage, electrical shock, injury or fire.

M

O

V

E

 A

N

D

 R

E

P

A

IR

ENTRUST

ENTRUST

PROHIBIT

2.1  Marks

2.2 Icons

2.3 

n

War ings

When there is something wrong or strange smell from the unit, please cut
off the power to the unit immediately.

2. Installation Precautions

2. Installation Precautions

 

Warinng:

Содержание Solace 1.25

Страница 1: ...SOLACE SERIES SWIMMING POOL DEHUMIDIFIER Installation Operation Manual...

Страница 2: ...nciple 3 5 Product Features 3 6 Hygrostat Control 4 Installation 5 Usage 5 1 Instruction for Operation Panel 5 2 Operation Instruction 6 Maintenance 7 1 PCB I O Port 7 2 Wiring Diagram Safety Precauti...

Страница 3: ...truction must be kept carefully and must always accompany the appliance If it is lost or damaged please contact the local technical service center 1 1 Fail to comply with these recommendations will in...

Страница 4: ...ated Do not put fingers or others into the fan or evaporator of the unit otherwise harm may be occurred OPERATION PROHIBITION SHUT OFF THE POWER When the unit needs to be moved or installed again plea...

Страница 5: ...agent or similarly qualified persons in order to avoid a hazard 7 It is forbidden to poke objects or anything else through the inlet or outlet grills 8 It is forbidden to dispose of or leave in the re...

Страница 6: ...20 240V 50Hz 10 36 See nameplate package label R410A 600g See 3 3 Operation Pressure Side High Operation Pressure Side Low Condensation Pipe Diameter 4 4 2 1 16 4 4 2 1 16 Model Rated Capaclty Air Vol...

Страница 7: ...mance Curve Solace 2 5 40 35 30 25 20 15 10 5 0 0 0 5 1 0 1 5 2 0 l h C 0 40 RH 2 5 60 RH 80 RH 40 35 30 25 20 15 10 5 0 0 0 5 1 0 1 5 2 0 l h C 0 40 RH 3 5 60 RH 80 RH 2 5 3 0 40 35 30 25 20 15 10 5...

Страница 8: ...coil of the refrigeration device condenses the water which is removed then the air is reheated by the hot coil This process works most effectively with higher ambient temperatures with a high dew poin...

Страница 9: ...e perfectly combined with your pool house 3 5 4 Newly design controller With simple operating display the newly developed controller makes the unit operation easier and more user friendly 3 6 1 The de...

Страница 10: ...as filter cleaning 4 2 Positioning 4 2 1 Avoid installing the unit in proximity to positions subject to exposure to direct sunlight sources of heat in places with oil fumes places subject to high freq...

Страница 11: ...6 Attention If the condensation water discharges directly into a container the condensate outlet should above the container to avoid immersing in the container Select a suitable size hose to connect t...

Страница 12: ...the target setting value DOWN 10 RH Defrosting Dehumidifying Press this button once to check the target setting value of relative humidity Press it again can decrease the target setting value Tips Wh...

Страница 13: ...Set the target value of relative humidity Press or to check the target relative humidity 11 RH RH Actual relative humidity The selected mode RH RH Press or again to change the target relative humidit...

Страница 14: ...ction Operation panel will display the failure codes when the unit gets some malfunctions Please refer to page15 to check the meaning of failure codes RH 5 2 3 Dehumidifying mode When the unit is in d...

Страница 15: ...an up the unit every six months Please take the following steps to clean up the strainer regularly 1 Pull out the grill A from the upside of it Fig 8 2 After that pull out the grill Fig 9 then lift th...

Страница 16: ...urn grille to the original place Fig 14 5 Clean up the unit outer with soft and damp rag Fig 15 To protect the paint coat of the unit please don t use rough sponge or corrosive detergent to do these W...

Страница 17: ...roubleshootings High pressure protection Condenser outlet temp overhigh Evaporator outlet temp sensor failure Humidity sensor failure Motor feedback signal failure Evaporator inlet temp sensor failure...

Страница 18: ...HUMI01 HUMI02 CN7 EEV PROG1 L N1 N_Comp N_Valve L_Comp Meaning To operation panel Reserved To fan motor DC To evaporator inlet outlet temp sensor To condenser outlet temp sensor To the build in hygro...

Страница 19: ...S TEMP2 HUMI01 HUMI02 TEMP 1 EEV CN1 FM PACC1001 t t 5K CdOT t 5K C1 Operation Panel TO POWER SUPPLY HPS CN7 CdOT Condenser OutletTemperature SS Sensitive Switch EvOT Evaporator Outlet Temperature EvI...

Страница 20: ...Code 20121115 0004...

Отзывы: