17
7.2 Wiring Diagram
7. Appendix
16
7.1 PCB I/O Port
NET2
TEMP1
CN1
HUMI02
PROG1
TEMP2
FM
EEV
L_Valve
L
L_Comp
N_Comp
N1
N_Valve
HUMI01
CN7
Explanation£
7. Appendix
NET1
NO
1
2
3
4
5
6
7
8
9
10
11
12
13
Ports
Cn1
CN4
NET1
NET2
FM
TEMP1
TEMP2
HUMI01
HUMI02
CN7
EEV
PROG1
L
N1
N_Comp
N_Valve
L_Comp
Meaning
To operation panel
Reserved
To fan motor(DC)
To evaporator inlet/outlet temp. sensor
To condenser outlet temp. sensor
To the build-in hygrostat
To the external hygrostat (optional)
To high pressure protection switch
To electronic expansion valve
Program burning port
To the Live Wire of power supply
To the Live Wire of compressor
Neutral Wire
CN4
CODE£ 201210220001
RED
BLK
WHT
N_Comp
L
FM
BLU
YEL
N1 N_Valve
L_Comp
BRN
BLU
Y/G
L
N
220-240V~/50Hz
EvOT
5
C
R
COMP
C
S
CR
CC
CS
BLK
RED
WHT
N
14
RHS
5K
EvIT
SS
TEMP 2
HUMI01
HUMI02
TEMP1
EEV
CN1
FM
PACC1001
t
t
5K
CdOT
t
5K
C1
Operation Panel
TO POWER SUPPLY
HPS
CN7
CdOT
£
Condenser Outlet Temperature
SS
£
Sensitive Switch
EvOT
£
Evaporator
Outlet Temperature
EvIT
£
Evaporator
Inlet Temperature
HUMIO 2
£
Can connect to an external RHS
FM
£
Fan Motor(DC)
EEV
£
Electronic Expansion Valve
RHS
£
Sensor of Relative Humidity
HPS
£
High Pressure Protection
Switch
PGND
EEV
Содержание Solace 1.25
Страница 1: ...SOLACE SERIES SWIMMING POOL DEHUMIDIFIER Installation Operation Manual...