11
© by NECTA VENDING SOLUTIONS SpA
0303 204-00
CONNECTING THE MACHINE
TO THE POWER SUPPLY
The machine is designed to operate under a single-phase
230 V~ voltage and is protected by T6.3 A fuses.
A power supply outlet must be provided for each machine
of the bank.
It is not possible to connect more than one machine to
the same power outlet.
Before making the connection, ensure that the rating of
each machine corresponds to that of the power grid, and
more specifically:
- the supply voltage rating must be within the range
recommended for the connection points;
- the main switches should be capable of withstanding
the peak load required, and at the same time ensure
proper omnipolar disconnection from the power grid
with an opening gap of the contacts of at least 3 mm.
The switches, the power outlets and the plugs must be
located in an easily accessible position.
The electrical safety of the machine is ensured only when
it is correctly earthed according to the safety standards in
force.
This fundamental safety requirement must be duly
verified, and if in doubt the system must be carefully
tested by qualified technicians.
The power supply cable is of the type with a fixed plug. Any
replacement of the power cable (see Fig. 16) should be
made by qualified and suitably trained personnel only
using cables type HO5 RN - F or HO5 V V-F or H07 RN-
F with a 3x1-1.5 mm
2
section.
ASSEMBLING THE VENDING MACHINES
To assemble master and slave vending machines do as
follows:
- Check that side ventilation grilles of the machines
equipped with a cooling unit are completely free.
Should the ventilation grilles be covered, even partially,
due to the layout to be adopted, it will be necessary to
fit the spacer (see Fig. 15) supplied with the machine.
Important notice!
The bank of machines should in any case be at least 4 cm
from the wall so that correct ventilation may be ensured.
- Ensure that the inclination of the machines does not
exceed 2°; If necessary provide proper levelling by
way of the adjustable feet included; the feet must be
adjusted to keep the machines side by side at the
same height.
- Secure the clamping bracket to the left side of the
master machine and position it next to the vending
machine; connect the connectors of the external can-
bus cable.
- Line up the front of the two vending machines, taking
care not to pull the external can-bus cable and not to
damage the cabinet with the protruding clamping
bracket.
- Secure the clamping bracket to the top panel of the
slave machine. Secure the two vending machines with
the screw at the base.
Fig. 15
1 - Spacer
2 - Can-bus cable connectors
3 - Adjustable feet
4 - Securing hole (to be drilled)
5 - Machine clamping bracket
Fig. 16
1 - Lift cover
2 - Cable clamp
3 - Power supply cable
Do not use adapters, multiple sockets and/or exten-
sions.
THE MANUFACTURER DECLINES ALL RESPONSI-
BILITY FOR ANY DAMAGE CAUSED BY NON-COM-
PLIANCE WITH THE ABOVE MENTIONED PRECAU-
TIONS.
Содержание Snakky SL
Страница 1: ...INSTALLATION USE AND MAINTENANCE MANUAL UK English Snakky SL DOC NO H 204U 00 EDITION 1 2003 03...
Страница 2: ......
Страница 54: ...Sx36901...
Страница 55: ...Snakky SL...
Страница 57: ...SCHEMA ELETTRICO WIRING DIAGRAM MACCHINA MACHINE Snakky SL...
Страница 58: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 59: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 60: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 61: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 62: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 64: ......