109
SYSTEM ANALYSIS
DIAGNOSTIC PROCEDURES
5
Symptoms
Outboard will not crank, starter does not
operate (electric start models):
•
Check condition of battery and cables (main
battery switch and cables). Make sure battery
cables are not reversed.
•
Confirm that B+ is present at “A” terminal (yel-
low/red wire) of starter solenoid with key switch
in the START position.
•
Proceed to
START CIRCUIT
on p. 112. Repair
starter or start circuit as needed.
Outboard cranks, will not start:
•
Use LED indicators of
EMM
for initial diagnostic
information.
•
Perform the
Static Spark Test
using the
Evinrude
Diagnostics Software program. Refer
to
IGNITION OUTPUT
on p. 115.
Results:
Steady spark on all cylinders and proper output
voltage on all ignition primary circuits:
•
Check operation of all fuel injectors. Refer to
FUEL COMPONENT TESTS
on p. 164.
•
Check fuel quality and that fuel is present at
injectors.
•
Refer to
FUEL COMPONENT TESTS
on p. 164
for fuel system pressure tests.
No spark on one or more cylinders:
•
Note cylinder with no ignition output. Refer to
IGNITION OUTPUT
on p. 115.
•
Monitor cranking RPM using the diagnostic pro-
gram (300 RPM minimum).
•
Check CPS operation (verify RPM reading.)
•
Perform ignition coil resistance test(s). Refer to
Ignition Coil Tests
on p. 128.
•
Use the
Evinrude
Diagnostics Software pro-
gram to check ignition voltage and 55 V alterna-
tor/injector voltage.
Outboard runs:
•
Use
Evinrude
Diagnostics Software program to
perform
Dynamic Tests
. See
Dynamic Tests
on p. 121.
•
Use the engine
Monitor
screen of the
Evinrude
Diagnostics Software program to observe circuit
voltages. Refer to
Engine Monitoring Informa-
tion
on p. 111.
•
Use the diagnostic software
Logging
function to
record engine data as a runability problem is
occurring.
•
Use an inductive timing light to monitor the
injector circuits and ignition primary circuits.
Refer to
Testing with Timing Light
on p. 110.
•
Use an inductive amp meter to monitor injector
circuit current. Compare readings of all circuits
to identify possible failure.
Logging Screen
005172
Содержание E-tec 75 HP
Страница 1: ......
Страница 16: ...16 INTRODUCTION NOTES NOTES Technician s Notes Related Documents Bulletins Instruction Sheets Other ...
Страница 84: ...84 MAINTENANCE NOTES NOTES Technician s Notes Related Documents Bulletins Instruction Sheets Other ...
Страница 122: ...122 SYSTEM ANALYSIS NOTES NOTES Technician s Notes Related Documents Bulletins Instruction Sheets Other ...
Страница 154: ...154 ELECTRICAL AND IGNITION NOTES NOTES Technician s Notes Related Documents Bulletins Instruction Sheets Other ...
Страница 233: ...233 POWERHEAD POWERHEAD VIEWS 10 POWERHEAD VIEWS Port Short Block Starboard Short Block ...
Страница 234: ...234 POWERHEAD POWERHEAD VIEWS Port Dressed Powerhead Starboard Dressed Powerhead ...
Страница 235: ...235 POWERHEAD POWERHEAD VIEWS 10 Front ...
Страница 236: ...236 POWERHEAD POWERHEAD VIEWS Rear ...
Страница 237: ...237 POWERHEAD POWERHEAD VIEWS 10 Top ...
Страница 238: ...238 POWERHEAD NOTES NOTES Technician s Notes Related Documents Bulletins Instruction Sheets Other ...
Страница 298: ...S 2 ...
Страница 336: ...A B C 5 1 2 3 6 4 5 1 2 3 6 4 5 1 2 3 6 4 DRC6165R MWS Instrument Wiring Harness 1 2 5 1 2 3 6 7 4 8 A B C ...
Страница 344: ......