Everwin PN100 Скачать руководство пользователя страница 8

 

 

 

 

AIR SUPPLY AND CONNECTIONS 

 

 
DO  NOT  USE  OXYGEN,  COMBUSTIBLE  GASES,  OR  BOTTLED  GASES  AS  A 
POWER  SOURCE  FOR  THIS  TOOL  AS  TOOL  MAY  EXSPLODE,  POSSIBLY 
CAUSING INJURY.   
 
 

FITTINGS: 

Install a male plug on the tool which is free flowing and which will release 

air pressure from the tool when disconnected from the supply source. 

 
HOSES: 

Air  hoses  should  have  a  minimum  of  150  p.s.i.  (10.6  kg/cm

2

)  working 

pressure  rating  or  150  percent  of  the maximum pressure that could be produced in 
the  air  system.  The  supply  hose  should  contain  a  fitting  that  will  provide  “quick 
disconnecting” from the male plug on the tool. 

 
SUPPLY SOURCE: 

Use only clean regulated compressed air as a power source for this 

tool.  NEVER  USE  OXYGEN,  COMBUSTIBLE  GASES,  OR  BOTTLED  GASES, AS A 
POWER SOURCE FOR THIS TOOL   AS TOOL MAY EXPLODE. 

 

REGULATOR: 

A pressure regulator with an operating pressure of 0 - 125 p.s.i. (0 - 

8.79  kg/cm

2

)  is  required  to  control  the operating pressure for safe operation of this 

tool. Do not connect this tool to air pressure which can potentially exceed 200 p.s.i. (14 
kg/cm

2

) as tool may fracture or burst, possibly causing injury. 

 
OPERATING  PRESSURE: 

Do  not  exceed  recommended  maximum  operating 

pressure  as  tool  wear  will  be  greatly  increased.  The  air supply must be capable of 
maintaining the operating pressure at the tool. Pressure drops in the air supply can 
reduce  the  tool’s  driving  power.  Refer  to  “TOOL  SPECIFICATIONS”  for  setting  the 
correct operating pressure for the tool. 
 

FILTER: 

Dirt and water in the air supply are major causes of wear in pneumatic tools. 

A filter will help to get the best performance  and  minimum  wear  from  the  tool.  The 
filter  must  have  adequate  flow  capacity  for  the  specific installation. The filter has to 
be kept clean to be effective in providing clean compressed air to the tool.  Consult the 
manufacturer’s instructions on proper maintenance of your filter. A dirty and clogged 
filter will cause a pressure drop which will reduce the tool’s performance.

 

 

LUBRICATION 

 

Frequent, but not excessive, lubrication is required for best performance. Oil added 
through the air line connection will lubricate the internal parts. Air Tool Lubricant, Mobil 
Velocite #10, or equivalent. Do not use detergent oil or additives as these lubricants 
will cause accelerated wear to the seals and bumpers in the tool, resulting in poor tool 
performance and frequent tool maintenance.

 

 

If no airline lubricator is used, add oil during use into the air fitting on the tool once or 
twice a day. Only a few drops  of  oil  at  a  time  is  necessary.  Too  much  oil  will  only 
collect inside the tool and will be noticeable in the exhaust cycle. 

 

      COLD WEATHER OPERATION 

 

 

 

 

CAUTION:

 

 
 

NOTE:

 

For cold weather operation, near and below freezing, the moisture in the air line may 
freeze  and  prevent  tool  operation.  We  recommend  the  use  permanent  antifreeze 
(ethylene glycol) as a cold weather lubricant. 

Do  not  store  tools  in  a  cold  weather  environment  to  prevent  frost  or  ice 
formation on the tools operating valves and mechanisms that could cause tool 
failure.  Test  tool  before  without  fasteners  prior  to  operations  to  ensure  no 
malfunction on the tool due to ice formation. 

Some commercial air line drying liquids are harmful to “O”-rings and seals – do 
not use these low temperature air dryers without checking compatibility.

 

 

Содержание PN100

Страница 1: ...NTENANCE MANUAL CE DECLARATION OF CONFORMITY 19 3 19 BEFORE OPERATING THIS TOOL ALL OPERATORS SHOULD READ AND STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE Everwin Pneumatic Corp ...

Страница 2: ...eference NOTE Additional safety measures may be required because of your particular application of the tool Contact your EVERWIN representative or distributor with any questions concerning the tool and its use Everwin Pneumatic Corp Taichung City Taiwan 41353 INDEX 1 Year Limited Warranty 3 CE Declaration of Conformity 4 Safety Instructions 5 Specifications 6 Technical Data 6 Operating Pressure Se...

Страница 3: ...seals driver blades bumpers pistons and piston rings b Failure due to normal wear neglect abuse misuse misapplication accidents over pressure usage improper storage shipping damages improper maintenance operation not within the operation manual s specification etc are not covered by this warranty c Labor charges loss repairs from improper maintenance and or usage of non EVERWIN parts are not cover...

Страница 4: ...IC CORP declaramos bajo nuestra sola responsabilidad que este producto esta en conformidad con las Directivas Europeas 2006 42 EC y con la normativa EN 792 13 Overensstemmelseserklæring CE Deklaration DANSK EVERWIN PNEUMATIC CORP erklærer herved at produktet er i overenstemmelse med nedenstående normer eller normative dokumenter 2006 42 EC i henhold til bestemmelserne i EU s direktiv EN 792 13 Öve...

Страница 5: ...the tool can remain charged with air after disconnecting and thus will be able to drive a fastener even after the air line is disconnected possibly causing injury Do not pull trigger or depress contact arm while connected to the air supply as the tool may cycle possibly causing injury Always disconnect air supply 1 Before making adjustments 2 When servicing the tool 3 When clearing a jam 4 When to...

Страница 6: ... AIR FITTING This tool uses a 3 8 18 N P T male plug The inside diameter should be 280 7 mm or larger The fitting must be capable of discharging tool air pressure when disconnected from the air supply OPERATING PRESSURE 70 TO 120 psi 5 to 8 kg cm2 Select the operating pressure within this range for best fastener performance DO NOT EXCEED THIS RECOMMENDED OPERATING PRESSURE TECHNICAL DATA AIR CONSU...

Страница 7: ... while keeping the trigger pulled thus driving a fastener each time the work is contacted This will allow rapid fastener placement on many jobs such as sheathing decking and pallet assembly All pneumatic tools are subject to recoil when driving fasteners The tool may bounce releasing the trip and if unintentionally allowed to recontact the work surface with the trigger still actuated finger still ...

Страница 8: ...s A filter will help to get the best performance and minimum wear from the tool The filter must have adequate flow capacity for the specific installation The filter has to be kept clean to be effective in providing clean compressed air to the tool Consult the manufacturer s instructions on proper maintenance of your filter A dirty and clogged filter will cause a pressure drop which will reduce the...

Страница 9: ...harge area of tool while the air supply is connected l Never point the tool at anyone else l Never engage in horseplay l Never pull the trigger unless nose is directed at the work l Always handle the tool with care l Do not pull the trigger or depress the trip mechanism while loading the tool LOADING THE TOOL Open the magazine Pull down door latch and swing door open Open the magazine Nail length ...

Страница 10: ...ot press the tool against the work with extra force Instead allow the tool to recoil off the work surface to avoid a second unwanted fastener Remove your finger from the trigger after each operation b RAPID FASTENER OPERATION To operate the tool in this manner hold the tool with the contact trip pointing towards but not touching the work surface Pull the trigger and then tap the contact trip again...

Страница 11: ...r press the contact trip against the work surface Pull the trigger THE TOOL MUST CYCLE IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL OBSERVE THE FOLLOWING FOR SAFE OPERATION l Use the this pneumatic tool only for the purpose for which it was designed like pallet crating sheathing decking applications l Never use this tool in a manner that could cause a fastener to be directed toward t...

Страница 12: ...ol problems for these symptoms trace the air supply from the tool to the supply source for restrictive connectors swivel fittings low points containing water and anything else that would prevent full volume flow of air to the tool DRIVER MAINTENANCE INSTRUCTIONS Worn driver causing poor quality or loss of power Wear on the driving tip will affect the nail drive giving symptoms of bent and incomple...

Отзывы: