background image

 

 

 

 

11 

TOOL OPERATION CHECK 

 

CAUTION: Remove all fasteners from tool before performing tool operation check. 

 

1.  CONTACT TRIP OPERATION: 

 

a.  With finger off the trigger, press the contact trip against the work surface. 

THE TOOL MUST NOT CYCLE. 

 

b.  Hold the tool off the work surface, and pull the trigger. 

THE TOOL MUST NOT CYCLE.

 

c.  With the tool off the work surface, pull the trigger. Press the contact trip against the work 

surface. 

THE TOOL MUST CYCLE.

 

d.  Without touching the trigger, press the contact trip against the work surface, then pull the 

trigger. 

THE TOOL MUST CYCLE.

 

2.  SEQUENTIAL TRIP OPERATION: 

 

a.  Press the contact trip against the work surface, without touching the trigger. 

THE TOOL MUST NOT CYCLE.

 

b.  Hold the tool off the work surface and pull the trigger.

 

THE TOOL MUST NOT CYCLE.

 

Release the trigger. The trigger must return to the trigger stop on the frame. 

c.  Pull the trigger and press the contact trip against the work surface. 

THE TOOL MUST NOT CYCLE.

 

d.  With finger off the trigger, press the contact trip against the work surface.    Pull the trigger. 

THE TOOL MUST CYCLE. 

 

IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL OBSERVE THE FOLLOWING 

FOR SAFE OPERATION 

 

l

 

Use the this pneumatic tool only for the purpose for which it was designed like pallet, crating, 
sheathing, decking applications

 

l

 

Never use this tool in a manner that could cause a fastener to be directed toward the user or others 
in the work area.

 

l

 

Do not use the tool as a hammer.

 

l

 

Always carry the tool by the handle. Never carry the tool by the air hose.

 

l

 

Do not carry this tool with the trigger depress when not in use

l

 

Do not alter or modify this tool from the original design or function.

 

l

 

Always be aware that misuse and improper handling of this tool can cause injury to yourself and 
others.

 

l

 

Never clamp or tape the trigger or contact trip in an actuated position.

 

l

 

Never leave a tool unattended with the air hose attached.

 

l

 

Do not operate this tool if it does not contain a legible WARNING LABEL.

 

l

 

Do not continue to use a tool that leaks air or does not function properly. Notify your 
distributor or representative if your tool continues to experience functional problems.

 

 

Содержание PN100

Страница 1: ...NTENANCE MANUAL CE DECLARATION OF CONFORMITY 19 3 19 BEFORE OPERATING THIS TOOL ALL OPERATORS SHOULD READ AND STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE Everwin Pneumatic Corp ...

Страница 2: ...eference NOTE Additional safety measures may be required because of your particular application of the tool Contact your EVERWIN representative or distributor with any questions concerning the tool and its use Everwin Pneumatic Corp Taichung City Taiwan 41353 INDEX 1 Year Limited Warranty 3 CE Declaration of Conformity 4 Safety Instructions 5 Specifications 6 Technical Data 6 Operating Pressure Se...

Страница 3: ...seals driver blades bumpers pistons and piston rings b Failure due to normal wear neglect abuse misuse misapplication accidents over pressure usage improper storage shipping damages improper maintenance operation not within the operation manual s specification etc are not covered by this warranty c Labor charges loss repairs from improper maintenance and or usage of non EVERWIN parts are not cover...

Страница 4: ...IC CORP declaramos bajo nuestra sola responsabilidad que este producto esta en conformidad con las Directivas Europeas 2006 42 EC y con la normativa EN 792 13 Overensstemmelseserklæring CE Deklaration DANSK EVERWIN PNEUMATIC CORP erklærer herved at produktet er i overenstemmelse med nedenstående normer eller normative dokumenter 2006 42 EC i henhold til bestemmelserne i EU s direktiv EN 792 13 Öve...

Страница 5: ...the tool can remain charged with air after disconnecting and thus will be able to drive a fastener even after the air line is disconnected possibly causing injury Do not pull trigger or depress contact arm while connected to the air supply as the tool may cycle possibly causing injury Always disconnect air supply 1 Before making adjustments 2 When servicing the tool 3 When clearing a jam 4 When to...

Страница 6: ... AIR FITTING This tool uses a 3 8 18 N P T male plug The inside diameter should be 280 7 mm or larger The fitting must be capable of discharging tool air pressure when disconnected from the air supply OPERATING PRESSURE 70 TO 120 psi 5 to 8 kg cm2 Select the operating pressure within this range for best fastener performance DO NOT EXCEED THIS RECOMMENDED OPERATING PRESSURE TECHNICAL DATA AIR CONSU...

Страница 7: ... while keeping the trigger pulled thus driving a fastener each time the work is contacted This will allow rapid fastener placement on many jobs such as sheathing decking and pallet assembly All pneumatic tools are subject to recoil when driving fasteners The tool may bounce releasing the trip and if unintentionally allowed to recontact the work surface with the trigger still actuated finger still ...

Страница 8: ...s A filter will help to get the best performance and minimum wear from the tool The filter must have adequate flow capacity for the specific installation The filter has to be kept clean to be effective in providing clean compressed air to the tool Consult the manufacturer s instructions on proper maintenance of your filter A dirty and clogged filter will cause a pressure drop which will reduce the...

Страница 9: ...harge area of tool while the air supply is connected l Never point the tool at anyone else l Never engage in horseplay l Never pull the trigger unless nose is directed at the work l Always handle the tool with care l Do not pull the trigger or depress the trip mechanism while loading the tool LOADING THE TOOL Open the magazine Pull down door latch and swing door open Open the magazine Nail length ...

Страница 10: ...ot press the tool against the work with extra force Instead allow the tool to recoil off the work surface to avoid a second unwanted fastener Remove your finger from the trigger after each operation b RAPID FASTENER OPERATION To operate the tool in this manner hold the tool with the contact trip pointing towards but not touching the work surface Pull the trigger and then tap the contact trip again...

Страница 11: ...r press the contact trip against the work surface Pull the trigger THE TOOL MUST CYCLE IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL OBSERVE THE FOLLOWING FOR SAFE OPERATION l Use the this pneumatic tool only for the purpose for which it was designed like pallet crating sheathing decking applications l Never use this tool in a manner that could cause a fastener to be directed toward t...

Страница 12: ...ol problems for these symptoms trace the air supply from the tool to the supply source for restrictive connectors swivel fittings low points containing water and anything else that would prevent full volume flow of air to the tool DRIVER MAINTENANCE INSTRUCTIONS Worn driver causing poor quality or loss of power Wear on the driving tip will affect the nail drive giving symptoms of bent and incomple...

Отзывы: