background image

 

 

 

 

NAIL LOADING 

 

 

EYE PROTECTION which conforms to ANSI/ CE specifications and provides 

protection against flying particles both from the FRONT and SIDE should 

ALWAYS be worn by the operator and others in the work area when 

connecting to air supply, loading,

 

operating or servicing this tool. Eye 

protection is required to guard against flying fasteners and debris, which 

could cause severe eye injury.

 

 

The employer and/or user must ensure that proper eye protection is worn. 

Eye protection equipment must conform to the requirements of the ANSI 

Z87.1 and 89/686/EEC, and provide both frontal and side protection. NOTE: 

Non-side shielded spectacles and face shields alone do not provide adequate 

protection. 

 

TO PREVENT ACCIDENTAL INJURIES: 

 

l

 

Never place a hand or any other part of the body in nail discharge area of 

tool while the air supply is connected. 

 

l

 

Never point the tool at anyone else. 

 

l

 

Never engage in horseplay. 

 

l

 

Never pull the trigger unless nose is directed at the work. 

 

l

 

Always handle the tool with care. 

 

l

 

Do not pull the trigger or depress the trip mechanism while loading the 

tool. 

 

LOADING THE TOOL:

 

 

 

 

 

 

 

Open the magazine:

   

Pull down door latch and swing door    

 

 

 

 

 

 

open. Open the magazine.  

 

 

 

 

 

 

 

Nail length adjustment: 

  The nail support can be moved    

 

 

 

 

 

 

        up and down to four settings. To change   

 

 

 

 

 

setting pull up on the  post  and  twist  to 

 

 

 

 

 

the correct step. The nail support should   

 

 

 

 

 

be adjusted  correctly to the position    

 

 

 

 

 

 

indicated in inches and millimeters inside     

 

 

 

 

 

magazine.   

 

 

Nail loading:

     

        Place a coil of nails over the post in the     

 

 

 

 

      magazine. Uncoil enough nails to reach the feed 

 

 

 

 

      pawl, and place the second nail between the   

 

 

 

 

        teeth on the feed pawl. The nail heads fit in slot 

 

 

 

 

        on nose. 

 

 

 

Swing Cover Closed

     

Check that latch engages. (If it does not engage,

 

Close the door

:                  check that the nail heads are in the slot on the  

 

 

 

 

    

 

nose.) 

 

 

Содержание PN100

Страница 1: ...NTENANCE MANUAL CE DECLARATION OF CONFORMITY 19 3 19 BEFORE OPERATING THIS TOOL ALL OPERATORS SHOULD READ AND STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE Everwin Pneumatic Corp ...

Страница 2: ...eference NOTE Additional safety measures may be required because of your particular application of the tool Contact your EVERWIN representative or distributor with any questions concerning the tool and its use Everwin Pneumatic Corp Taichung City Taiwan 41353 INDEX 1 Year Limited Warranty 3 CE Declaration of Conformity 4 Safety Instructions 5 Specifications 6 Technical Data 6 Operating Pressure Se...

Страница 3: ...seals driver blades bumpers pistons and piston rings b Failure due to normal wear neglect abuse misuse misapplication accidents over pressure usage improper storage shipping damages improper maintenance operation not within the operation manual s specification etc are not covered by this warranty c Labor charges loss repairs from improper maintenance and or usage of non EVERWIN parts are not cover...

Страница 4: ...IC CORP declaramos bajo nuestra sola responsabilidad que este producto esta en conformidad con las Directivas Europeas 2006 42 EC y con la normativa EN 792 13 Overensstemmelseserklæring CE Deklaration DANSK EVERWIN PNEUMATIC CORP erklærer herved at produktet er i overenstemmelse med nedenstående normer eller normative dokumenter 2006 42 EC i henhold til bestemmelserne i EU s direktiv EN 792 13 Öve...

Страница 5: ...the tool can remain charged with air after disconnecting and thus will be able to drive a fastener even after the air line is disconnected possibly causing injury Do not pull trigger or depress contact arm while connected to the air supply as the tool may cycle possibly causing injury Always disconnect air supply 1 Before making adjustments 2 When servicing the tool 3 When clearing a jam 4 When to...

Страница 6: ... AIR FITTING This tool uses a 3 8 18 N P T male plug The inside diameter should be 280 7 mm or larger The fitting must be capable of discharging tool air pressure when disconnected from the air supply OPERATING PRESSURE 70 TO 120 psi 5 to 8 kg cm2 Select the operating pressure within this range for best fastener performance DO NOT EXCEED THIS RECOMMENDED OPERATING PRESSURE TECHNICAL DATA AIR CONSU...

Страница 7: ... while keeping the trigger pulled thus driving a fastener each time the work is contacted This will allow rapid fastener placement on many jobs such as sheathing decking and pallet assembly All pneumatic tools are subject to recoil when driving fasteners The tool may bounce releasing the trip and if unintentionally allowed to recontact the work surface with the trigger still actuated finger still ...

Страница 8: ...s A filter will help to get the best performance and minimum wear from the tool The filter must have adequate flow capacity for the specific installation The filter has to be kept clean to be effective in providing clean compressed air to the tool Consult the manufacturer s instructions on proper maintenance of your filter A dirty and clogged filter will cause a pressure drop which will reduce the...

Страница 9: ...harge area of tool while the air supply is connected l Never point the tool at anyone else l Never engage in horseplay l Never pull the trigger unless nose is directed at the work l Always handle the tool with care l Do not pull the trigger or depress the trip mechanism while loading the tool LOADING THE TOOL Open the magazine Pull down door latch and swing door open Open the magazine Nail length ...

Страница 10: ...ot press the tool against the work with extra force Instead allow the tool to recoil off the work surface to avoid a second unwanted fastener Remove your finger from the trigger after each operation b RAPID FASTENER OPERATION To operate the tool in this manner hold the tool with the contact trip pointing towards but not touching the work surface Pull the trigger and then tap the contact trip again...

Страница 11: ...r press the contact trip against the work surface Pull the trigger THE TOOL MUST CYCLE IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL OBSERVE THE FOLLOWING FOR SAFE OPERATION l Use the this pneumatic tool only for the purpose for which it was designed like pallet crating sheathing decking applications l Never use this tool in a manner that could cause a fastener to be directed toward t...

Страница 12: ...ol problems for these symptoms trace the air supply from the tool to the supply source for restrictive connectors swivel fittings low points containing water and anything else that would prevent full volume flow of air to the tool DRIVER MAINTENANCE INSTRUCTIONS Worn driver causing poor quality or loss of power Wear on the driving tip will affect the nail drive giving symptoms of bent and incomple...

Отзывы: