7700 MultiFrame Manual
7707OO-2-OC Telecom and Datacom Optical Wavelength Converter
Page-18
Revision
1.3
6.3. V
ISTA
LINK
®
CONTROLLED PARAMETERS
The following parameters can be remotely controlled through the VistaLINK
®
interface.
Parameter Description
Data Mode
Select telecom or datacom data rates
Data Rate
Select the data rate/standard from available
telecom and datacom types, automatic and bypass
modes
Laser Mode
Select continuous or discontinuous laser mode for
LINE and EQUIPMENT side lasers (separate
settings for each)
Optical Threshold
Optical power threshold for low optical power alarm
trap – separate settings for LINE and EQUIPMENT
receivers
Table 6-2: VistaLINK
®
Controlled Parameters
6.4. V
ISTA
LINK
®
TRAPS
The following traps can be VistaLINK
®
enabled and monitored.
Parameter Description
Laser Fault
Indicates deficient operation of the optical output
line and/or equipment laser
Input Signal Presence
Indicates missing signals at LINE and/or
EQUIPMENT inputs
Optical Power
Indicates LINE and/or EQUIPMENT optical input
power below threshold setting
Table 6-3: VistaLINK
®
Traps