7700 MultiFrame Manual
7707OO-2-OC Telecom and Datacom Optical Wavelength Converter
Page-14
Revision
1.3
CTRL
RATE
DCOM
FC-2125MBPS
FC-1062MBPS
FC-531MBPS
FC-266MBPS
FC-133MBPS
ETH-125MBPS
XAUI-3125MBPS
XAUI-3187MBPS
ESCON-200MBPS
BYP
FC-2125MBPS
Fiber Channel, 2.125 Gb/s
FC-1062MBPS
Fiber Channel, 1.062 Gb/s
FC-531MBPS
Fiber Channel, 531 Mb/s
FC-266MBPS
Fiber Channel, 266 Mb/s
FC-133MBPS
Fiber Channel, 133 Mb/s
ETH-125MBPS
Fast Ethernet
XAUI-3125MBPS
XAUI 3.125 Gb/s
XAUI-3187MBPS
XAUI 3.187 Mb/s
ESCON-200MBPS
ESCON
BYP
Reclocker is bypassed
4.2.8. Selecting the Output Laser Enable Mode
In some applications, it is beneficial to disable the laser output with no input signal present. Alternatively, it
may be preferable to maintain an optical output signal, even with no input. The 7707OO-2-OC supports
both modes of operation.
To configure the laser enable mode, select the
CTRL
menu item in the first menu level. Use the toggle
switch to select the
LASR
menu item and press the pushbutton. Then use the toggle switch to select either
the
LINE
side laser or the equipment (
EQUP
) side laser and press the pushbutton. The toggle switch can
then be used to change the mode of operation. Press the pushbutton to apply the displayed selection and
return to the first menu level. For the sake of brevity, only the
LINE
side laser will be discussed in the
manual.
CTRL
LASR
LINE
CONT
DISC
CONT
Continuous operation. Laser is always enabled, even without an
active input signal.
DISC
Discontinuous operation. Laser is disabled when no active input
signal is detected.
4.2.9. Setting the Orientation of the Text on the Card Edge Display
The
DISP
option allows the user to set a horizontal or vertical orientation for the card edge display. To set
the display orientation, select the
CTRL
menu item in the first menu level, then use the toggle switch to
show the
DISP
menu selection and use the pushbutton to select it. Use the toggle switch to change
between
HORZ
and
VERT
. Press the push button to make your selection.
CTRL
DISP
HORZ
VERT
HORZ
Horizontal display used when the module is housed in the one-rack
unit 7701FR frame or the stand-alone enclosure.
VERT
Vertical display used when the module is housed in the three-rack
unit 7700FR frame.