4.2.3. Displaying the Data Standard Detected at the EQUIPMENT Input
To display the data standard detected at the EQUIPMENT input, select the
STAT
menu item in menu level
1, then use the toggle switch to display the
EQUP
option
and press the pushbutton to select it. Use the
toggle switch to then display the
RATE
option
and press the pushbutton to select it.
STAT
EQUP
RATE
RATES PER MODE
BYP
LOS
Rates per mode:
OC48-2488MBPS
OC48/STM16, 2.488 Gb/s
OC12-622MBPS
OC-12/STM-4, 622 Mb/s
OC3-155MBPS
OC-3/STM-1, 155 Mb/s
ETH-1250MBPS
Gigabit Ethernet
FC-2125MBPS
Fiber Channel, 2.125 Gb/s
FC-1062MBPS
Fiber Channel, 1.062 Gb/s
FC-531MBPS
Fiber Channel, 531 Mb/s
FC-266MBPS
Fiber Channel, 266 Mb/s
FC-133MBPS
Fiber Channel, 133 Mb/s
ETH-125MBPS
Fast Ethernet
XAUI-3125MBPS
XAUI 3.125 Gb/s
XAUI-3187MBPS
XAUI 3.187 Mb/s
ESCON-200MBPS
ESCON
BYP
EQUIPMENT input is set to bypass (non-reclock) mode
LOS
No signal present
4.2.4. Displaying the Optical Power at the EQUIPMENT Input
The 7707OO-2-OC module can measure and display the input optical power over a range of -1dBm to
–40dBm at increments of 1dBm. To display the optical power detected at the EQUIPMENT input, select
the
STAT
menu item in menu level 1, then use the toggle switch to display the
EQUP
option
and press the
pushbutton to select it. Use the toggle switch to then display the
PWR
option
and press the pushbutton to
select it.
STAT
EQUP
PWR
OVER
-1 TO -40
LOW
OVER
Indicates optical input power exceeding –1dBm
-1 to –40
Optical input power within this range
LOW
Input optical power low (< -40 dBm)
4.2.5. Displaying the Firmware Version
To display the version of the 7707OO-2-OC’s embedded firmware, select the
STAT
menu item in menu
level 1, then use the toggle switch to display the
VER
option
and press the pushbutton to select it. The
display will show the following:
VER x.x BUILD xxx