5782DEC
Professional H.264 and MPEG-2 Decoder
WEBEASY
Revision 1.0
Page - 43
5.11. FAULTS
The 5782DEC has a Fault Page where the following information can have traps set and will display if
there is a fault present. Red indicates there is a fault present and green indicates there is no fault
present.
Figure 5-14: WebEASY
®
– Faults Tab
CC Fault Present
Video CC Error:
This control checks whether a continuity counter fault is currently present.
Audio 1-4 CC Error:
This control checks whether a continuity counter fault is currently present.
Memory Self Test Fault Present
Memory Self Test:
This control checks whether a memory self test fault is currently present.
Input Fault Present
TS Input Missing:
This control checks whether an input fault is currently present.
TS Sync Byte Missing:
This control checks whether a TS Sync Byte is missing.
Input Bit Error:
This control is used to enable and disable input traps.
SCTE 35 Data Present:
This control is used to enable and disable input traps.
SCTE 104 Data Inserted:
This control is used to enable and disable input traps.
Video Timestamp Error:
This control is used to enable and disable input traps.
Audio Timestamp Error 1-8:
This control is used to enable and disable input traps.
Содержание 5782DEC
Страница 2: ...This page left intentionally blank ...
Страница 6: ...5782DEC Professional H 264 and MPEG 2 Decoder Page ii Revision 1 0 This page left intentionally blank ...
Страница 10: ...5782DEC Professional H 264 and MPEG 2 Decoder Page vi Revision 1 0 This page left intentionally blank ...
Страница 12: ...5782DEC Professional H 264 and MPEG 2 Decoder Page 2 Revision 1 0 OVERVIEW Figure 1 1 5782DEC Block Diagram ...
Страница 54: ...5782DEC Professional H 264 and MPEG 2 Decoder Page 44 Revision 1 0 WEBEASY This page left intentionally blank ...