Section 2 Quick Setup Guide
ITEM
DESCRIPTION
1
Switch. This switch serves as the main power switch for the unit. If a severe fault or short takes place, this breaker switch will trip. If the breaker trips,
find and rectify fault before attempting to power the unit back on. If the switch does not reset, contact Everlast.
2
Fan. Keep the fan area clear and allow a minimum of
18”
(500mm) clearance for proper air circulation and maximum duty cycle. The fan should run
continuously.
3
Regulator/Filter/Water Trap. This regulates the cutting pressure of the unit. To adjust: Pull up firmly but gently on the regulator knob until the detent
clicks (about
1/8”
or 3mm). Rotate clockwise to increase pressure. Rotate counterclockwise to decrease pressure. Observe the pressure and indicator
lights on the front of the machine to reach the ideal pressure for the process you have selected. Push the knob back down after adjusting to lock
-
in the
pressure setting. WARNING! Do not supply more than 90 psi to the regulator or damage and/or severe injury may occur.
4
Gas Inlet. The gas inlet has a push
-
to
-
connect type fitting. When initially installing, make sure the connecting tubing from the regulator to the inlet is
squarely cut on the end so that a good seal is formed. If the tubing must be removed, the outer collar must be pressed in gently to release the tubing.
Hold the collar while removing the tubing.
5
Ground Bolt. This is to be used in cases where High Frequency (H.F.) interference is being caused or where a bonded ground is indicated by code. This
should be connected directly to an outside copper clad rod driven into the ground with at least a # 12 gauge wire connecting the two together. All metal
parts inside the building should be grounded as well, including pipes, tables, and even metal siding to help prevent stray H.F. emissions from causing
interference or damage to the electronics and surrounding equipment.
6
NEMA 6
-
50 Power Plug. This is the standard 240V, single phase plug used for welders/plasma cutters in North America. This plug has only three
wires and is used by all manufacturers for this type application. This unit requires and uses no neutral. There are two power legs and one ground
(middle U
-
shaped, or rounded prong). Do not attempt to rewire or adapt this plug for other applications. This unit is also supplied with a 240V to 120V
adapter for 120V use. No changeover or alteration of the unit is required to step down to 120V input. The unit automatically senses the change and
adapts the circuits to operate on 120V. Consult with a licensed electrician before installing power service to the unit.
Refer to Article 630 of the NEC for
information concerning wiring of welders and plasma cutting units.