Section 2 Quick Setup Guide
EVERLAST
Regulator reads in Cubic Feet per Hour (CFH) for US
and Canada. Other regions may read in Liters per
Minute (LPM)
CO
2
NEMA 6
-
50P
L1,BLACK; HOT
GAS
INLET
L2,WHITE; HOT
GREEN GROUND (220/240V 1
NOTICE:
The supplied plug is a NEMA 6
-
50P, This is the standard plug for
welders in the USA and Canada. It is a 50 amp 3 prong plug. There is
only a ground and no neutral in a welder circuit. For 120V use, use the
supplied adapter. No switching or change of wiring is necessary for
120V use if the supplied adapter is used.
IMPORTANT!
Always consult a licensed Electrician and local codes before adding or modifying any
existing wiring. Do not modify the welder wiring! Refer to Article 630 of the NEC for
more information concerning proper wiring of welders.
NOTICE:
The unit has a common connection point for both the plasma air supply and
the TIG shielding gas. This means the gas hoses must be swapped back and
forth when changing between processes. Do not run Argon through the
plasma regulator. You make a manifold system to connect both TIG shield-
ing gas and plasma air at the same time by using an Inert gas Y
-
valve or
series of ball valves. The rear connection is a standard
5/8”
CGA fitting for
inert gas/TIG welding. These are available almost anywhere welding supplies
are sold, both locally and online.
NOTICE:
TIG shielding gas must be 100% argon or Ar/He mix. If using Ar/He, never
exceed 25% Helium. Never use CO2 or Ar/CO2 or other Ar mixes.
TIG Gas Connections and Power Connection