NAV IP Access controller
20
Figure
2
‐
11
Connecting
to
the
Door
Open
Button
Connect
the
wires
from
the
door
open
button
to
the
terminal
block
on
the
door
module.
You
can
either
connect
the
wires
to
Pin
8
and
9
(Door
1)
or
Pin
24
and
25
(Door
2)
on
the
terminal
block.
Figure
2
‐
12
2.2.4
Connecting
to
the
Fire
Alarm/
Alarm
Input
You
can
either
connect
the
alarm
inputs
to
the
main
module
or
the
alarm
module.
On
the
Main
Module
The
main
module
provides
two
general
alarm
inputs,
connecting
to
Pin
1
and
2
or
Pin
2
and
3
on
the
terminal
block.
The
GND
terminal
is
shared
by
these
two
input
signals.
Both
inputs
can
be
configured
as
either
fire
alarm
input
or
general
alarm
input.
Figure
2
‐
13
On
the
Alarm
Module
The
alarm
modules
provide
8
alarm
inputs.
The
alarm
input
pins
provided
by
the
alarm
module
includes
Pin
1,
3,
4,
6,
19,
21,
22,
24.
For
details
on
pin
assignment,
please
refer
to
1.6.2
Terminal
Block
and
LEDs
on
Alarm
Module
.
Following
is
an
example
on
connecting
the
alarm
input
to
the
alarm
module.
Door
module
EXIT
8
9
24
25
GND
Input
Signal