NAV IP Access controller
18
Figure
2
‐
8
Each
door
module
can
provide
+12V
voltage
for
two
readers.
Twisted
cable
is
recommended
to
connect
the
controller
and
readers.
The
maximum
transmission
distance
between
the
reader
and
controller
depends
on
the
gauge
of
the
cable
and
the
specification
of
the
reader.
Please
read
the
reader
user
manual
carefully
before
installing
the
cable
for
the
readers.
Note:
It
is
strongly
recommended
to
use
one
connection
format
in
a
multi
‐
reader
system,
i.e.
all
the
readers
are
connected
to
the
door
modules
through
RS
‐
232
or
Wiegand
connection.
Multiple
connection
formats
could
cause
compatibility
problems
to
the
system.
2.2.3
Connecting
to
the
Door
Lock,
Sensor
and
Open
Button
Connecting
to
the
Door
Lock
The
Electric
strikes
and
magnetic
locks
are
used
to
keep
doors
locked
unless
the
system
grants
access
or
the
user
sets
the
doors
to
remain
unlocked.
One
strike
or
magnetic
lock
is
required
for
each
door.
These
locks
must
be
powered
separately
from
the
readers.
The
mounting
instructions
for
strikes
and
magnetic
locks
vary
depending
on
the
manufacturer
and
type
of
lock.
Please
consult
the
instructions
included
with
the
door
hardware
when
installing.
Once
the
locks
are
installed,
follow
the
instructions
below
to
connect
them
to
the
controller.
Electric
Strike
Connect
the
wires
from
the
electric
strike
to
the
terminal
block
on
the
door
module.
You
can
either
connect
the
wires
to
Pin
11
and
12
(Door
1)
or
Pin
27
and
28
(Door
2)
on
the
terminal
block.
Yellow
Brown
Green
Black
Red
GND
+12V
Reader_Data0
Reader_Data1
Reader Ctrl
Ever Access
#
0
*
WXYZ
T U V
PQRS
7
M N O
6
5
J K L
4
G H I
3
D E F
A B C
2
1
9
8
1
2
3
4
5
17
18
19
20
21
Door