NAV IP Access controller
55
Panic
Open
alarms
are
designed
to
allow
users
who
are
forced
to
enter
a
building
under
duress
to
silently
trigger
an
alarm.
When
the
door’s
access
schedule
is
configured
as
PIN
needed,
for
example:
“Card
or
PIN”
or
“Card
plus
PIN”,
cardholders
can
type
in
their
panic
PIN
to
trigger
a
panic
open
event
in
the
system.
The
panic
PIN
is
the
cardholder’s
original
PIN
plus
any
two
digits.
For
example,
Sam’s
PIN
is
12345678.
He
can
type
in
any
two
more
digits
following“12345678”
as
the
panic
PIN,
such
as
“1234567800”.The
time
setting
for
panic
open
event
is
shown
in
the
below
figure:
Press
numeric
keys
to
input
the
specified
alarm
time
for
the
event.
Press
to
confirm
and
press
to
discard
the
change
just
made.
5.6.4.21
Event Alarm Action Setting
Press
at
the
below
screen
to
configure
event
alarm
action
setting.
The
event
alarm
action
defines
which
alarm
output
can
be
triggered
by
the
event.
As
we
explained
before,
NAV
Controller
can
take
main
modules,
up
to
4
door
modules
and
1
alarm
module,
total
18
alarm
output.
Users
will
be
able
to
configure
the
event
to
trigger
any
one
or
multiple
outputs
from
those
18
alarm
outputs.
The
event
alarm
action
setting
includes
three
submenus,
shown
in
below.
The
alarm
output
setting
on
these
three
screens
are
the
similar.
For
example,
the
fire
alarm
event
actions
on
door
module
will
look
like:
The
top
line
indicates
the
event
to
be
configured.
The
bottom
line
is
the
setting
of
alarm
outputs
on
4
door
modules.
Y
indicates
there
is
alarm
output
(relay
energized)
and
N
indicates
there
is
no
alarm
output
(relay
not
energized).
R
refers
specifically
to
alarm
output
on
the
door
module,
indicating
that
alarm
output
will
be
generated
only
if
the
event
occurs
on
the
corresponding
door.
The
above
example
means
the
alarm
output
relay
at
door
1
will
be
energized
if
door
forced
open
event
happens
on
any
door,
the
alarm
output
relay
at
door
2
does
not
respond
to
any
door
forced
open
event,
and
same
as
door
4
to
8.
Door
3
indicates
the
alarm
output
relay
on
door
3
will
be
energized
if
and
only
if
the
door
3
got
a
forced
open
event.
Note
“R”
option
for
alarm
output
does
not
apply
to
alarm
module
and
main
module,
since
they
don’t
naturally
correspond
to
a
door
control.
In
the
above
menu,
press
numeric
key
1~8
to
toggle
the
alarm
output
actions
of
this
event
on
the
door
module
among
Y,
N,
and
R
(only
for
door
module).
Press
and
to
navigate
to
other
alarm
action
settings.
Door Forced Open
YNRNNNN
Event Alarm action
on Alarm Module
Event Alarm action
on Door Module
Event Alarm action
on Main Module
EventAlarm action
Setting
Panic Open
000Min 10Sec