4
Pre-installation
PERFORMANCE DATA
SKU
HP
DISTANCE OF
PUMP ABOVE
WATER
DISCHARGE PRESSURE
10
20
30
40
50
GALLONS PER MINUTE
236
5
ft. 56 45 31 17 --
10
ft. 49 42 28 12.5
--
15
ft. 48 39 24 8 --
20
ft. 45 37 20 --
--
1
1/2
5
ft. 67 61 48 33 --
10
ft. 61 56 45 26 --
15
ft. 56 54 44 20 --
20
ft. 46 44 37 11 --
2
5
ft. 83 71 56 41 17
10
ft. 77 67 54 36 8
15
ft. 76 65 50 32 --
20
ft. 75 62 48 28 --
1
092
1001
092
1001
238
092
1001
241
Outlet
1 1/2 in.
Inlet
2 in.
1 1/2 in.
2 in.
2 in.
2 in.
(continued)
Suction/Discharge
pipe
Thread sealant
tape
Check valve
Elbow
Union
Gate valve
Priming tee
MATERIALS REQUIRED (NOT INCLUDED)
1-1/2 in. or 2 in.
2 in.
1-1/2 in. or 2 in.
1-1/2 in. or 2 in.
1-1/2 in. or 2 in.
1-1/2 in. or 2 in.
Note: Please select suitable materials based on inlet and outlet size.(see page 4)
Pressure gauge
Pressure relief valve
Min
Min
Min
(recommended)
2 in. NPT
2 in. NPT strainer
basket with
1/8 in. holes
Before using this pump, ensure you have the appropriate items based on the installation technique from the following pages.
IMPORTANT: Do not use pipe or fittings on suction side of pump less than 2 in.! This will restrict suction and reduce priming ability and
performance.
Foot valve
with strainer