EVER EASYLINE AVR USB UPS Range Operating Manual
Type 02
2017-01-27 12:25
Technical Service, tel.: +48 61 6500 400
www.ever.eu
16
The UPS operates in buffer (battery) mode).
The icon
flashes every second.
The UPS operates in battery loading mode. The UPS is
not supplying power to output sockets. This state
occurs when the UPS power cable is plugged to the
mains socket, but the UPS is not switched on with the
front panel button.
The icon
is active in case of a fault other than
overload or short circuit.
Table 2. Sound signaling of specific states of the UPS unit
UPS unit status
Sound signaling
Battery mode
Short sound every 10 seconds
Low battery
Short sound every second
Overload
Short sound every half second
Failure state
Continuous signal
FIRST START-UP
CAUTION!
The UPS may only be connected to a ~230V mains socket
with a grounding connection (a bolt). The facility's electrical system to
which the UPS unit is connected must be fitted with overload and short-
circuit protection.
After unpacking, place the device in its work place and connect the power lead to the
mains in order to charge the battery up. When the power lead is connected to the
mains socket, the UPS automatically starts in the battery charging mode (see
description of signals in Table 1). It is recommended to charge the battery for at least
6 hours. You can then proceed carry out subsequent installation activities. In order to
do so: