The Harmonizer
®
Programmer’s Manual
©
1999-2008 Eventide, Inc.
Page 80 of 97
Release 1.3
INTER-DSP COMMUNICATION FOR H8000 AND ORVILLE
Control signals can be sent from one DSP to the other in
Orville.
7600 family users should note that they only have a
single DSP, so will probably want to skip this section.
The
c_bridge
module accepts four control signal inputs.
Control signal outputs that are connected to these inputs appear at the
other
DSP’s “global control
outputs” and at the control
outputs
of a
c_bridge
module in the
other
DSP. A DSP’s global control
outputs are located on the
IN
module as seen on the screen to the right
(notice that we’re in
ctrlonly
display
mode)
.
For example, load the program
Inter-DSP Send
from the
“
Programming
” bank into DSP A. A
knob
module is
connected to the first input of a
c_bridge
module in as
shown to the right.
Additionally, the
knob
module’s
userobject
output is
connected to the
head
module so that the
knob
module’s
parameter shows up in the
PARAMETER
area as shown to the
right.
Now load the program
Inter-DSP Receive
from the
“
Programming
” bank into DSP B. A
monitor
module is
connected to global control output 1.
Additionally, the
monitor
module’s
userobject
output is connected to the
head
module so that it
shows up in the
PARAMETER
area as shown to the right.
You can see for yourself that changing the
Send Value
in DSP
A alters the
Receive value
in DSP B. Of course, you could
<insert>
a
c_bridge
module in DSP B to send control
signals to DSP A
at the same time that DSP A is sending
control signals to DSP B!
Содержание H7600