The Harmonizer
®
Programmer’s Manual
©
1999-2008 Eventide, Inc.
Page 51 of 97
Release 1.3
Feedback
Add a
percentknob
module and connect its
control output to
amp2
on the
mix
module. Then
double click on it. Change the
specifier
s as
shown to the right.
•
The
mix
module’s control inputs accept a
value from -1 to +1
(negative values invert the
phase of the applied signal)
. Recall that the
percentknob
module’s output will be
1/100th that of its displayed value. Thus we
can display the feedback as a percentage and
still get the appropriate fractional control
output.
•
The “
%%
” in the
menu statement
is necessary to allow a
single
“
%
” symbol to appear on the
Harmonizer’s display. This is because “%” is a special symbol that tells the Harmonizer that
numeric
information is to be displayed in what follows. Thus, to tell it that you actually want to
display a “%” symbol requires two.
Depth
Add a
knob
module and connect its control
output to
gain2
on the
mixer
module. Then
double click on it to alter its
specifier
s to match
those shown to the right.
•
The control inputs on the
mixer
module
accept values from -100 to zero.
Rate
Add a
knob
module and connect its control
output to
freq
on the
LFO
module. Then double
click on it to alter its
specifier
s to match those
shown to the right.
•
The
freq
control input on the
LFO
module
accepts a value between zero and 1000.