Evco EVC30S40 Скачать руководство пользователя страница 3

Evco S.p.A. • Code 104C30S40E02 • page 3/6

Before the conclusion of the count (of the time established with
parameter P21) the buzzer is activated, for the time established with
parameter P20.
If there is a power cut during the count, the same will start again from
the beginning when the power supply is restored.
For EVC70S40X7XXX00 / 03.
The cooking timer allows to start the countdown.
The display shows the value during counting, the 

L3

 LED will flash

and the

 min

 LED is on.

Before the conclusion of the count (of the time established with
parameter P4) the buzzer is activated, for the time established with
parameter P3.
The acoustic output is activated at the conclusion of the count until the

B6

 key is pressed (or the encoder button is pressed).

If there is a power cut during the count, the same will start again from
the beginning when the power supply is restored.

7.2

Setting and start-up of the cooking timer

For EVC30S40J7XXX02 / 03.
• make sure that the instrument is in on status and that no procedure

is in progress

• press

B6

: the display shows the corresponding value and the

min

LED will flash

• press

B2

or

B5

within 15 s; see also parameters P17,
P18 and P19

• press

B6

: the instrument will exit the procedure, the 

L3

 LED will

flash and the 

min

 LED will switch-on and the timer will be

started.

To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
For EVC30S40J7XXX04.
• make sure that the instrument is in on status and that no procedure

is in progress

• turn the encoder: the display shows the corresponding value and

the 

min

 LED will flash

• turn the encoder within 15 s; see also parameters P17, P18 and P19
• press the encoder button: the instrument will exit the procedure, the

L3

 LED will flash and the 

min

 LED will switch-on and the timer will

be started.

To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
For EVC30S40J7XXX05.
• make sure that the instrument is in on status and that no procedure

is in progress

• press

B1

: the display shows the corresponding value and the 

min

LED will flash

• turn the encoder within 15 s; see also parameters P17, P18 and

P19

• press

B1

: the instrument will exit the procedure, the 

L3

 LED will

flash and the 

min

 LED will switch-on and the timer will be

started.

To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
For EVC70S40X7XXX00.
• make sure that the instrument is in on status and that no procedure

is in progress

• press

B1

: the display shows the corresponding value and the 

min

LED will flash

• press

B2

or

B5

within 15 s; see also parameters P0,
P1 and P2

• press

B6

: the instrument will exit the procedure, the 

L3

 LED will flash

and the 

min

 LED will switch-on and the timer will be started.

Alternatively:
• make sure that the instrument is in on status and that no procedure

is in progress

• press

B1

: the display shows the corresponding value and the 

min

LED will flash

• press

B2

or

B5

within 15 s; see also parameters P0,
P1 and P2

• press

B1

or do not operate for 15 s: the instrument will leave the
procedure.

To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
Successively:
• press

B6

: the 

L3

 LED will flash and the 

min

 LED will switch-on and

the timer will be started.

For EVC30S40X7XXX03.
• make sure that the instrument is in on status and that no procedure

is in progress

• turn the encoder: the display shows the corresponding value and

the 

min

 LED will flash

• turn the encoder within 15 s; see also parameters P0, P1 and P2
• press the encoder button: the instrument will leave the procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
Successively:
• press the encoder button: the 

L3

 LED will flash and the 

min

 LED will

switch-on and the timer will be started.

7.3

Interrupting the cooking timer

For EVC30S40J7XXX02 / 03 and for EVC70S40X7XXX00.
• press

B6

: the 

L3

 LED and the 

min

 LED will switch off.

For EVC30S40J7XXX04 and for EVC70S40X7XXX03.
• press the encoder button: the 

L3

 LED and the 

min

 LED will switch

off.

For EVC30S40J7XXX05.
• press

B1

: the 

L3

 LED and the 

min

 LED will switch off.

8

STEAM SEQUENCE (for EVC70S40X7XXX01 / 02)

8.1

Preliminary considerations

The steam sequence allows to start the countdown of three times.
On the conclusion of the count of a time, the instrument automatically
passes to the next count.
During the countdown of the first three times (successively also called
“time t1”) the display shows the value, the 

L1

 LED flashes. If the param-

eter P9 is set at 1 the

 min

 LED is on and the timer 1 output is on.

During the countdown of the second three times (successively also
called “time t2”) the display shows the value, the 

L2

 LED flashes. If the

parameter P9 is set at 1 the

 min

 LED is on and the outputs are switched

off.
During the countdown of the third three times (successively also called
“time t3”) the display shows the value, the 

L3

 LED flashes. If the param-

eter P9 is set at 1 the

 min

 LED is on and the timer 2 output is on.

On conclusion of the countdown of the time t3, the buzzer is activated
for the tie established with parameter P12.
The functioning of the instrument on conclusion of the count of time
t3 depends on parameter P10.
If there is a power cut during the count, the same will start again from
the beginning when the power supply is restored.

8.2

Setting times t1, t2 and t3

For EVC70S40X7XXX01.
• make sure that the instrument is in on status and that no procedure

is in progress

• press

B1

: the display shows the time t1 and the 

L1

 LED will flash

• press

B2

or

B5

within 15 s; see also parameters P0,
P1 and P2

• press

B1

: the display will show the time t2, the 

L1

 LED switches-

off and the 

L2

 LED will flash

• press

B2

or

B5

within 15 s; see also parameters P6, P7 and P8

• press

B1

: the display will show the time t3, the 

L2

 LED switches-off

and the 

L3

 LED will flash

• press

B2

or

B5

within 15 s; see also parameters P3,
P4 and P5

• press

B1

: the instrument will exit the procedure and 

L3

 LED will

switch-off.

To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
For EVC70S40X7XXX02.
To set time t1:
• make sure that the instrument is in on status and that no procedure

is in progress

• press

B3

: the display shows the time t1 and the 

L1

 LED will flash

• press

B2

or

B5

within 15 s; see also parameters P0,
P1 and P2

• press

B3

: the instrument will exit the procedure and 

L1

 LED will

switch-off.

To set time t2:
• make sure that the instrument is in on status and that no procedure

is in progress

• press

B1

: the display shows the time t2 and the 

L2

 LED will flash

• press

B2

or

B5

within 15 s; see also parameters P6, P7 and
P8

• press

B1

: the instrument will exit the procedure and 

L2

 LED will

switch-off.

To set time t3:
• make sure that the instrument is in on status and that no procedure

is in progress

• press

B4

: the display shows the time t3 and the 

L3

 LED will flash

• press

B2

or

B5

within 15 s; see also parameters P3,
P4 and P5

• press

B4

: the instrument will exit the procedure and 

L3

 LED will

switch-off.

To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).

8.3

Starting the steam sequence

• make sure that the instrument is in on status and that no procedure

is in progress

• press

B6

: the 

L1

 LED will flash and if the parameter P9 is set at 1 the

min

 LED will switch on.

8.4

Interrupting the steam sequence

press

B6

: the 

L1

L2

 or 

L3

 LED will switch off and if parameter P9

is set at 1 also the

 min

LED.

9

QUICK HEATING (for EVC30S40J7XXX02 /
03 / 05)

9.1

Preliminary considerations

The quick heating allows to reach the work set point as quickly as
possible, supplying 100% power at the top and the floor (i.e. excluding
switch-on of the top and floor outputs in a cyclical mode with the
benefit of continuous switch-on).
When the chamber temperature reaches the “work set point -
temperature established with parameter P23”, the function is
interrupted.
If there is a power cut during the quick heating, the same will start-up
again when the power supply is restored.

9.2

Activation of quick heating

• make sure that the instrument is on, that there is no procedure in

progress and that the parameter P22 is set at 1

• press

B6

for 4 s.

9.3

Interruption of quick heating in manual mode

• make sure no procedure is in progress
• press

B6

for 4 s.

10

AUXILIARY OUTPUT (for EVC30S40J7XXX01)

10.1

Preliminary considerations

The functioning mode of the auxiliary output depends on
parameters P6 and P7.
If parameter P6 is set at 0, pressing the 

B6

 key when the instrument is

on causes the output to switch on and when pressed again, causes it
to switch off.
If parameter P6 is set at values different to 0 and parameter P7 is set at 0,
pressing the 

B6

 key when the instrument is on causes the output to

switch on for the time established with parameter P6.
If parameters P6 and P7 are set at values different to 0, the output will
be switched on cyclically (parameter P6 establishes the duration of
switch-on and parameter P7 that of switch-off). Pressing the 

B6

 key

when the instrument is on causes the cyclical activity to start and pressing
the 

B5

 key causes its interruption.

The 

L2

 LED supplies indications regarding the state of the auxiliary

output, see chapter 11.

11

SIGNALS

11.1

Signals

LED

MEANING

L1

For EVC30S40J7XXX00 / 01.
temperature regulation LED
if on, the output for temperature regulation will be off.
if flashing, the output for temperature regulation will be on.
For EVC30S40J7XXX02 / 03 / 04 / 05.
top LED
if it is on, the top output will be on
if flashing, the top set point setting is in progress or that of
the power supplied at the top
For EVC70S40X7XXX01 / 02.
time t1 LED
if on, the setting of time t1 is in progress
if flashing, the time t1 count is in progress

L2

For EVC30S40J7XXX01.
Auxiliary output LED
if it is on, the auxiliary output will be on
For EVC30S40J7XXX02 / 03 / 04 / 05.
floor LED
if it is on, the floor output will be on
if flashing, the floor set point setting is in progress or that
of the power supplied at the floor
For EVC70S40X7XXX01 / 02.
time t2 LED
if on, the setting of time t2 is in progress
if flashing, the time t2 count is in progress

L3

For EVC30S40J7XXX02 / 03 / 04 / 05 and for
EVC70S40X7XXX00 / 03.
cooking timer LED
if it is on, the cooking timer count will be concluded
if flashing, the cooking timer count is in progress
For EVC70S40X7XXX01 / 02.
time t3 LED
if on, the setting of time t3 is in progress
if flashing, the time t3 count is in progress

L4

For all models.
on/stand-by LED
if it is on, the instrument is in the stand-by status
For all models.
Power supply cut off LED
if flashing, if a power cut should occur when the instrument
is on or (during a time count), press a key (or turn the
encoder) to switch the LED off.

min

For EVC30S40J7XXX02 / 03 / 04 / 05 and for
EVC70S40X7XXX00 / 03.
minutes LED
if on, the cooking timer count is in progress
if flashing, cooking timer setting is in progress
For EVC70S40X7XXX01 / 02.
minutes LED
if it is on, the unit of measurement of the time will be the
minute (parameter P9)

°

C

For EVC30S40J7XXX00 / 01 / 02 / 03 / 04 / 05.
Degrees Celsius LED
if it is on, the unit of measurement of the temperatures will
be the degree Celsius (parameter P0)

°

F

For EVC30S40J7XXX00 / 01 / 02 / 03 / 04 / 05.
Degrees Fahrenheit LED
if it is on, the unit of measurement of the temperatures will
be the degree Fahrenheit (parameter P0)

12

ALARMS

12.1

Alarms

CODE MEANING

H-t

For EVC30S40J7XXX00 / 01.
use temperature alarm
Solutions:
• press 

B2

 (or turn the encoder) to display the use tem-

perature

• see parameters P8 and P9

Содержание EVC30S40

Страница 1: ... regulation The output activity depends mainly on the temperature of the chamber the work set point and the parameter P5 Top If functioning with 1 measurement input parameter P3 1 the out put is measured in a cyclical mode preferably when the floor output is off the parameter P10 establishes the cycle time Using the procedure given in paragraph 6 2 1 it is possible to set the duration of output sw...

Страница 2: ...g the floor set point For EVC30S40J7XXX02 if the parameter P3 is set at 0 make sure that the instrument is in on status and that no procedure is in progress press B5 the display shows the corresponding value and the L2 LED will flash press B2 or B5 within 15 s see also parameters P5 P6 and P8 do not operate for 15 s the L2 LED will switch off and the instrument will exit the procedure To exit the ...

Страница 3: ...2 the L1 LED switches off and the L2 LED will flash press B2 or B5 within 15 s see also parameters P6 P7 and P8 press B1 the display will show the time t3 the L2 LED switches off and the L3 LED will flash press B2 or B5 within 15 s see also parameters P3 P4 and P5 press B1 the instrument will exit the procedure and L3 LED will switch off To exit the procedure in advance do not operate for 15 s any...

Страница 4: ... deactivated For EVC30S40J7XXX02 03 04 05 if the parameter P3 is set at 1 chamber probe error Solutions the same as the previous case but relative to the chamber probe Main consequences the top output and the floor output will be deactivated AL2 For EVC30S40J7XXX02 03 04 05 if parameter P3 is set at 0 floor probe error Solutions the same as the previous case but relative to the floor probe Main co...

Страница 5: ...t differential if P3 0 minimum top set point and floor set point if P3 1 minimum work set point firmware code 3 time t3 maximum value enabling of the use temperature alarm code H t 1 YES duration of auxiliary output switch on see also P7 if P3 0 maximum top set point and floor set point if P3 1 maximum work set point firmware version code 3 time t2 predefined value temperature over which the use t...

Страница 6: ...dified DESCRIPTION predefined value of the power supplied at the floor percentage of P10 only if P3 1 see also P9 firmware code 3 enabling of the use temperature alarm code H t 1 YES firmware version code 3 temperature over which the use temperature alarm is activated code H t see also P14 firmware revision code 3 size displayed when the instrument is on 0 if P3 0 top temperature if P3 1 chamber t...

Отзывы: