Changing set room temperature
Press P1 button to change the set room temperature.
The display shows the set room temperature (SET temperature value). Press P1 and P2 buttons to decrease or increase, respectively, the temperature value.
The value is saved after approx. 5 seconds and the display goes back to normal. Otherwise, press P3 to exit.
Room temperature reaches set value (SET temperature value)
Once the set room temperature value has been reached, the stove heat output is automatically set to the minimum value. During this phase the display shows the
message "MODULAT-". If room temperature falls below the set value (Set temperature value), the stove will go back to the "UORK" mode and to the previously
set heat output (Set heat output value).
Stand-by
When enabled in the menu, the STAND-BY function allows the stove to be switched off after complying with the following conditions.
It is enabled if the room temperature exceeds the relevant set value (Set room temperature value) during the period of time set by Pr44 parameter to which Pr43
parameter must be added. The message "GO-STBY" appears on the display followed by the minutes left. At the end of the period of time set by Pr44 parameter
the message " UAIT COOLING " will appear on the display. During this phase the Auger tube is off (Auger tube LED off), the exchanger switches off once the
threshold set by Pr15 parameter has been reached and the ON/OFF LED flashes. When fume temperature reaches the threshold set by Pr13 parameter, the
stove goes into the STAND-BY mode and the message "STOP ECO TEMP GOOD" scrolls on the display. The Auger tube (Auger tube LED off), the exchanger
(exchanger LED off) and the exhaust blower are off. If room temperature falls below the set value (Set room temperature value) plus the threshold set by Pr43
parameter, the stove switches back on.
Stove switching off
Hold P3 button down to switch off the stove. The display shows the message "CLEANING FINAL”. The Auger tube motor switches off (Auger tube LED off), the
exhaust blower speed is set by Pr08 parameter and the ON/OFF LED flashes. The exchanger blower remains on (exchanger LED on) until the fume temperature
falls below the value set by Pr15 parameter. If, at the end of the period of time set by Pr39 parameter, the fume temperature remains below the threshold set by
Pr10 parameter, the stove will switch off and the message "Off" appears on the display.
ALARMS
Should any malfunctioning be detected, the control board reports the problem in question: the alarm LED switches on (alarm LED on) and the buzzer goes off.
In case of alarm, the stove is always immediately switched off
EXCEPT FOR THE POWER OUTAGE ALARM
, the alarm status is reached at the end of the period of time set by Pr11 parameter and can be cleared by holding
P3 button down. Whenever an alarm is cleared, the stove starts a switching-off phase for safety reasons. The alarm LED (alarm LED on) will remain on and the
buzzer, if enabled, will sound intermittently during the entire alarm phase. Should the alarm not be cleared, the stove will in any case be switched off and the alarm
message will remain on the display.
AL1 BLAC-OUT
- Power outage alarm
Power outage may occur with stove in working mode. When power resumes, if the power outage period has been lower than the value set by a 20” parameter,
the stove will restart in the
WORKING
mode. Otherwise the relevant alarm will be triggered. The message “Al1 BLAC-OUT” (scrolls on the display and the stove
switches off.
AL2 PROBE EXHAUST
- Fume temperature sensor alarm
The alarm is triggered in case of faulty fume sensor. The stove goes into the alarm status and the alarm LED switches on (alarm LED on). The message “AL2
PROBE EXHAUST” will scroll on the display and the stove will switch off.
AL3 HOT EXHAUST
- Fume overheating alarm
The alarm is triggered whenever the fume sensor detects a temperature higher than a fixed set value, which may not be modified by means of a parameter. The
message “AL3 HOT EXHAUST” appears on the display and the stove switches off.
AL4 FAN FAILURE
- Faulty fume encoder alarm
The alarm is triggered in case of exhaust blower failure. The stove goes into the alarm status and the message “AL4 FAN FAILURE
” will scroll on the display.
AL5 NO LIGHTIN-
- Ignition failure alarm
The alarm is triggered in case of ignition phase failure. This occurs when fume temperature does not exceed the value set by Pr1 3 parameter at the end of the
period of time set by PR0 1 parameter. The message “AL5 NO LIGHTIN-
" scrolls on the display and the stove goes into the alarm status.
AL6 NO PELLET
- No pellet alarm
The alarm is triggered when fume temperature falls below the value set by Pr13 parameter with stove in working mode. The message “AL6 NO PELLET
" scrolls
on the display and the stove goes into the alarm status.
AL7 SAFETY THERMAL
- Thermal safety overheating alarm
The alarm is triggered whenever the general safety thermostat detects a temperature exceeding the trigger threshold. The thermostat switches off the Auger tube,
being connected in series to its power supply, the control board reports the alarm status (alarm LED on) by showing the message “AL7 SAFETY THERMAL” on
the display and the stove switches off.
AL8 FAILURE DEPRESS
- No negative pressure alarm
The alarm is triggered whenever the external pressure switch detects a pressure higher value below the trigger threshold. The pressure switch switches off the
Auger tube, being connected in series to each other, and the control board reports the alarm status (alarm LED on) by showing the message “AL8 FAILURE
DEPRESS” on the display. The stove switches off.
05.4 ELECTRONICS WITH 6 BUTTON LED DISPLAY N. 100 p. 42 F-1
(Pellet stoves – Pellet inserts)
PROPER FUNCTIONING AND CONTROL ADJUSTMENT DEVICES
Console
The control board can be managed by simply pressing a few buttons on the control panel. A display and the LED indicators inform about the stove operational
status. When in programming mode all the parameters that can be modified using the buttons are shown on the display.
DESCRIPTION OF PANEL
Button (P1)
Room temperature increase
Button (P2)
Room temperature decrease
Button (P3)
Set / menu
Button (P4)
ON / OFF
Button (P5)
Heat output decrease
Button (P6)
Heat output increase
Display (D1):
It displays the detected room temperate and the time at start-up.
During working mode, it shows the heat output set by the user.
When modifying user/technician parameters, it shows the value of the
parameter in question.
Led (L1)
Chrono enabled - CHRONO
Led (L2)
Auger tube moving – AUGER TUBE ON
Led (L3)
Remote control receiver - REMOTE CONTROL
Led (L4)
Thermostat on – ROOM TEMP SETTING
Led (L5)
Flashing during temperature setup or when inside menus - SET
Display (D2):
It shows the board status during start-up phase.
During working mode, it shows the temperature set by the user.
When modifying user/technician parameters, it shows the label of the
parameter in question.
Содержание ANGLE
Страница 2: ......
Страница 5: ...F 1 F 2 F 3 F 4...
Страница 6: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Страница 37: ...10 CERTIFICA...
Страница 39: ......
Страница 42: ...F 1 F 2 F 3 F 4...
Страница 43: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Страница 75: ......
Страница 77: ......
Страница 80: ...F 1 F 2 F 3 F 4...
Страница 81: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Страница 113: ......
Страница 115: ......
Страница 119: ...F 1 F 2 F 3 F 4...
Страница 120: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Страница 151: ......
Страница 153: ......
Страница 157: ...F 1 F 2 F 3 F 4...
Страница 158: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Страница 189: ......
Страница 191: ......
Страница 194: ...F 1 F 2 F 3 F 4...
Страница 195: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Страница 227: ......
Страница 229: ......
Страница 233: ...F 1 F 2 F 3 F 4...
Страница 234: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Страница 266: ......
Страница 268: ......
Страница 303: ......
Страница 305: ......