Switching on the stove again
It will be possible to switch the stove back on only at the end of the safety period of time set by Pr38 and if the fume temperature has reached a value below Pr13.
WHAT HAPPENS IN CASE OF….
Pellet ignition failure
If pellets do not ignite, the display shows the alarm message (NO LIGHTIN-).
Power outage (BLACK-OUT)
When the power is resumed after an outage, the stove enters the (CLEANING FINAL) phase and waits until the fume temperature reaches a value below Pr13.
If the power outage duration (BLACK-OUT) is longer than T, the stove switches off.
ALARMS
In case of malfunctioning the control board reports the problem and activates various procedures depending on the type of alarm. In case of alarm, the stove is
always immediately switched off. The alarm status is reached after a set period of time Pr11 and can be cleared by pressing the P4 button.
ALARM ACTIVE ALARM FLOW –
Abstract alarm
It occurs when the same sensor, which signals the alarm, is dirty, or the chimney is blocked.
ALARM ACTIVE PROBE EXHAUST -
Fume temperature sensor alarm
The alarm is triggered when the fume temperature sensor is not working properly or is disconnected. During the alarm, the stove switches off.
ALARM ACTIVE HOT EXHAUST -
Fume overtemperature alarm
Is triggered whenever the fume sensor detects a temperature exceeding 220°C.
The stove switching-off phase starts immediately.
ALARM ACTIVE NO LIGHTIN -
Ignition failure alarm
The alarm is triggered whenever ignition fails. The stove switching-off phase starts immediately.
ALARM ACTIVE NO PELLET -
Stove switching-off during working mode alarm
If during normal working mode, the flame goes out and the fume temperature falls below the minimum threshold (Pr13 parameter).
The stove switching-off phase starts immediately.
ALARM ACTIVE FAILURE DEPRESS -
Auger tube safety pressure switch alarm.
If the pressure switch (meter pressure) detects a value higer the trigger threshold, it immediately switches off the Auger tube (to which it is
connected in series) while the control board acquires this change in status through the AL2 clamp in CN4. The message “FAILURE
DEPRESS” appears on the display and the stove is immediately switched off.
ALARM ACTIVE WAIT COOLING -
Power outage
ALARM ACTIVE SAFETY THERMAL -
General thermostat alarm
If the general safety thermostat detects a value exceeding the trigger threshold, it immediately switches off the Auger tube (to which it is connected in series),
while the control board acquires this change in status through the AL1 clamp in CN4. The message
SAFETY THERMAL
is displayed and the system shuts down.
Unscrew the black cap behind the stove and press the button to reset the contact.
ALARM ACTIVE FAN FAILURE
- Damage exhaust blower alarm
Whenever the exhaust blower stops working properly, the stove switches off immediately and the message
FAN FAILURE
.The stove switching off phase starts
immediately.
05.3 ELECTRONICS WITH 3 BUTTON DISPLAY N.100 p. 42 F-4
(Pellet stoves – Pellet stove with oven – Pellet kitchen – Pellet kitchen with oven)
PROPER FUNCTIONING AND CONTROL ADJUSTMENT DEVICES
Console
The control board can be managed by simply pressing a few buttons on the control panel. A display and the LED indicators inform about the stove operational
status. When in programming mode all the parameters that can be modified using the buttons are shown on the display.
DESCRIPTION OF PANEL
LED (L0)
Room temperature setting
LED (L1)
Heat output setting
LED (L2)
Chrono
LED (L3)
ON/OFF
LED (L4)
Alarm
LED (L5)
Auger tube/exchanger / ignition plug
THE MENU
Hold P1 button down to access the menu. It includes several items and levels to access settings and control board programming.
Menu M1 – SET CLOCK
Push and hold the (P1) button until you see the M1 writing, confirm with the ON/OFF (P3) button. With the (P1) and (P2) buttons change the current day and push
the power button, set the hour and push ON/OFF (P3), set the minutes and push ON/OFF (P3), set the current day in number and push ON/OFF (P3), set the
current month and push ON/OFF (P3), set the current year and at this point to confirm and exit push and hold the ON/OFF (P3) button until you see the current
hour.
Menu M2 – SET CHRONO
Submenu M2 – 1 CHRONO ENABLE
Push and hold the (P1) button until you see the M1 writing, push the (P2) button until M2, confirm with ON/OFF (P3) and you will see the Menu M2-1, confirm
with ON/OFF (P3) and with the arrow (P1) put ON to activate the general chrono; go back by holding down the ON / OFF (P3) button, and with (P2) choose
the program to be activated.
Submenu M2 – 2 PROGRAM DAY
Two ON-OFF cycles fixed for every day
Submenu M2 – 3 PROGRAM UEEK
Four ON-OFF cycles and for every schedule you must select the days
Submenu M2 – 4 PROGRAM U-END
Two ON-OFF cycles for Saturday and Sunday
BUTTON (P1)
decrease / menu / room temperature setting
BUTTON (P2)
increase / stove status/heat output setting
BUTTON (P3)
ON/OFF exit/confirm
DISPLAY (D1)
status/heat output/parameter
Содержание ANGLE
Страница 2: ......
Страница 5: ...F 1 F 2 F 3 F 4...
Страница 6: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Страница 37: ...10 CERTIFICA...
Страница 39: ......
Страница 42: ...F 1 F 2 F 3 F 4...
Страница 43: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Страница 75: ......
Страница 77: ......
Страница 80: ...F 1 F 2 F 3 F 4...
Страница 81: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Страница 113: ......
Страница 115: ......
Страница 119: ...F 1 F 2 F 3 F 4...
Страница 120: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Страница 151: ......
Страница 153: ......
Страница 157: ...F 1 F 2 F 3 F 4...
Страница 158: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Страница 189: ......
Страница 191: ......
Страница 194: ...F 1 F 2 F 3 F 4...
Страница 195: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Страница 227: ......
Страница 229: ......
Страница 233: ...F 1 F 2 F 3 F 4...
Страница 234: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Страница 266: ......
Страница 268: ......
Страница 303: ......
Страница 305: ......