Operating the Converter
4-15
590+ Series DC Digital Converter
Starting and Stopping Methods
Stopping Methods
Note:
•
If the Converter is “non-regenerative” (2-quad - 591+) it effectively coasts to a stop once the
current demand reverses.
•
If the Converter is “regenerative” (4-quad - 590+) then it can stop faster because it uses
energy from the load, i.e. reverse current is allowed to flow.
Normal Stop and Program Stop are only relevant for a “regenerative” controller.
The parameters STOP TIME and PROG STOP TIME have associated timers which initiate a
Coast Stop after the timed period.
The Coast Stop has direct control of the Run relay with no intervening
electronics.
All associated parameters can be found in the STOP RATES menu.
Terminal
Terminal
Terminal
Terminal Description
Description
Description
Description
Function
Function
Function
Function
Parameter
Parameter
Parameter
Parameter
Priority
Priority
Priority
Priority
B9
Coast Stop
Motor coasts to rest
--
Overrides Program
Stop and Normal Stop
B8
Program Stop Motor decelerates at
Program Stop rate
PROG STOP TIME Overrides Normal
Stop
C3
Start/Run
(Normal Stop)
Motor decelerates at
Normal Stop rate
STOP TIME
--
Incorrect Speed Response
Under damped response
Speed
Time
8
causing overshoot or `ringing'
Incorrect Speed Response
Over damped response takes a
long time to reach Steady Sate
Speed
Time
8
Correct Response
Critically Damped Response with no more than 4% of
maximum speed from first overshoot to first undershoot
Speed
Time
4%
9
MMI Menu Map
1
SETUP PARAMETERS
2
STOP RATES
Содержание 590+ Series
Страница 16: ...1 4 Getting Started 590 Series DC Digital Converter ...
Страница 58: ...3 32 Installing the Converter 590 Series DC Digital Converter Figure 3 11 Frame 2 40A 165A Stack Assembly ...
Страница 76: ...3 50 Installing the Converter 590 Series DC Digital Converter ...
Страница 110: ...5 14 The Operator Station 590 Series DC Digital Converter ...
Страница 194: ...7 10 Trips and Fault Finding 590 Series DC Digital Converter ...
Страница 208: ...9 6 Control Loops 590 Series DC Digital Converter ...
Страница 236: ...10 28 Parameter Specification Table 590 Series DC Digital Converter ...
Страница 260: ...11 24 Technical Specifications 590 Series DC Digital Converter ...
Страница 274: ...12 14 Certification for the Converter 590 Series DC Digital Converter ...
Страница 300: ...15 2 The Default Application 590 Series DC Digital Converter ...
Страница 308: ......