General technical data
11.4 Digital control
a) current control
settings
according to factory specifications or motor data
current limits
speed control menu or PROG-key
externally through fixed voltage
0..10V = 0..100%; can be normed
resolution
10 bit
b) speed control
settings
speed control menu or PROG key
differential setpoint input analog
Usoll = 10 V, can be normed; Ri = 10k
resolution (including sign)
12 bit
digital setpoint input
via interfaces
c) position control
11.5 Digital communication
RS232 - service interface
COM1
optional
RS232 / RS 422 / RS 485
on SUB D - socket
COM2
CAN, Profibus DP,
SUCOnet K
on SUB D - socket
Interbus S
on SUB D - socket (OUT)
Interbus S (Remote IN)
additional SUB D plug
standard-protocol
19200 baud, 8 databits,1 startbit, 1 stopbit,
parity: even
11.6 Resolver evaluation / transmitter principle
General:
The specified data refer to the combination of the standard resolver interface;
operated with the Eurotherm resolver R 21-T05, R15-T05
carrier frequency
ft = 5 kHz
linearity error of the actual value signal
1%
ripple of the actual value signal
2%
max. position resolution for one revolution
16384 Incr. 14 bit
absolute position accuracy
+/- 0,52 °
relative position accuracy
+/- 0.08 °
Содержание 635
Страница 63: ...Product manual Model 635 DER u 635 K DER 07 01 05 06 E V1002 doc 63 10 Block circuit diagram ...
Страница 72: ...72 Product manual Model 635 DER u 635 K DER 07 01 05 06 E V1002 doc 14 Certificates ...
Страница 73: ...Product manual Model 635 DER u 635 K DER 07 01 05 06 E V1002 doc 73 Certificates ...
Страница 74: ...74 Product manual Model 635 DER u 635 K DER 07 01 05 06 E V1002 doc Certificates ...
Страница 75: ...Product manual Model 635 DER u 635 K DER 07 01 05 06 E V1002 doc 75 Certificates ...
Страница 77: ...Product manual Model 635 DER u 635 K DER 07 01 05 06 E V1002 doc 77 16 Notes ...