ReliaGATE 10-14 User manual Rev. 0-10
15 Power supply. How to turn ON/OFF and reset the product
7. Connect Pin 3 (Key Signal) to "Power IN +".
The ReliaGATE 10-14 automatically turns ON and the LED 6 (POWER) turns ON
NOTICE
When connecting Pin 3 to "Power IN +", keep it connected for at least 10 seconds.
If you disconnect "Power VIN +" from the Pin 3 before 10 seconds have passed, the start-
up procedure will not be completed correctly and an immediate and unsafe power down
will occur.
8. To keep the ReliaGATE 10-14 turned ON, make sure that Pin 3 keeps connected to "Power VIN +".
15.4
How to turn OFF the product
There two ways of turning OFF the product according to the status of the DIP-switch SW# 1 in the Service
Panel:
l
If SW# 1 is ON (the Ignition Key control enabled), to turn OFF the ReliaGATE 10-14 OFF, follow
these steps:
1. Disconnect the KEY pin from Power IN +. The DynaGATE 10-12 performs a safe shut down
2. Remove the power from the Power IN connector.
l
If SW# 1 is OFF (Ignition Key monitoring only), to turn the ReliaGATE 10-14 OFF:
o
Remove the power from the Power IN connector.
See also:
l
"The Ignition Key" on page 73 "DIP-switches meaning" on page 44
l
"DIP-switches meaning" on page 44
.
15.5
How to reduce the power consumption of the product
To reduce the power consumption of the ReliaGATE 10-14, turn OFF the radio interfaces and disable
unnecessary services that contribute to overall system power consumption.
15.6
How to hardware reset the product
To trigger a hardware reset of the ReliaGATE 10-14, push the hardware reset pushbutton available in the
Service Panel.
85 / 90
Содержание ReliaGATE 10-14 Series
Страница 4: ...This page has been intentionally left blank...
Страница 12: ...This page has been intentionally left blank...
Страница 16: ...This page has been intentionally left blank...
Страница 18: ...This page has been intentionally left blank...
Страница 20: ...This page has been intentionally left blank...
Страница 22: ...This page has been intentionally left blank...
Страница 28: ...This page has been intentionally left blank...
Страница 36: ...This page has been intentionally left blank...
Страница 80: ...This page has been intentionally left blank...
Страница 86: ...This page has been intentionally left blank...
Страница 88: ...This page has been intentionally left blank...
Страница 89: ...ReliaGATE 10 14 User manual Rev 0 10 Notes NOTES 89 90...