9
Wiring diagram(Applicable to model:
ED-GC604SS
)
(ED-GC705SS, ED-GC905SS)
Wiring diagram for
Remove the
internal earthing\
4. Gas Connection (OPTIONAL)
Install in accordance with relevant gas standards and/or codes of practice applicable.
Connect the elbow fitting to the appliance gas manifold connection, and check that seals between the elbow and
manifold connection are in place and in good condition.
⚫
For Natural gas: connect the natural gas appliance regulator (pictured opposite) with integral test point using
approved gas thread tape or compound to the elbow fitting.
⚫
For Universal LPG: see page 12
Ensure the supply connection point, test point and natural gas regulator adjustment
screw (for Natural gas installation) are accessible for testing and/or adjustment with the hotplate in the installed
position.
Where a flexible hose assembly is used, ensure it is approved to
AS/NZS 1869, Class B. Any hose assembly used must be restrained
from accidental contact with the flue outlet of an under bench oven.
This hose assembly shall be suitable for connection to a fixed
consumer piping outlet located as follows:
Hotplates at a point 800 mm to 850 mm above the floor and in the
region outside the width of the appliance to a distance of 250 mm.
After connecting to gas, check for leaks using soapy
solution, never a naked flame.
Fit the duplicate data plate (supplied in separate bag) on a surface adjacent to the hotplate, for example, the
Inlet connection region for flexible hose
Содержание ED-GC604SS
Страница 1: ...Flush Top surface Built in Stainless Steel Gas Cooktop ED GC905SS ED GC705SS ED GC604SS...
Страница 11: ...11...