7
Installation
Before Installation:
⚫
Before cutting into any bench tops, ensure the minimum clearances to walls, adjacent surfaces and
overhead surfaces required by the relevant gas appliance installation code (see above) will comply.
Dimensions are specified in millimeters (mm)
Overhead cupboards and range hood = 650 mm.
Side and rear clearance = 200 mm to any burner edge.
Overhead exhaust/ceiling fan = 750 mm
Horizontal surfaces adjacent the hob = less than or equal to the hob height.
Ensure there is sufficient clearance to fit the regulator and/or flexible hose connection with the hotplate in
the installed position.
Before the appliance is installed into the cabinet, please make sure any transit protection is removed.
When you have installed the hob, make sure that
⚫
The GPO (general purpose outlet) must always be in an accessible position.
⚫
The supply connection point, test point and natural gas regulator adjustment screw (for Natural gas
installation) are accessible for testing and/or adjustment with the hotplate in the installed position.
1. Cupboard Cutting
Bench top thickness, 30
– 40 mm (3 – 4 cm).
TO BE INSTALLED ONLY BY AN AUTHORIZED PERSON.