![Eurotec ETUF-9060R Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/eurotec/etuf-9060r/etuf-9060r_user-manual_2440316018.webp)
Page | 16
User Manual
Backflush (Concentrate Side Discharge)
After the module is drained, the first backflush conducted. Filtrate water is pumped from the filtrate/ backwash
tank back into the membranes through the lumen side (i.e. a “reverse” of the feed flow direction). Backflush is
conducted to further remove the foulants from the surface of the membrane as well as those trapped within
the pores. The backflush water is discharged through the concentrate drain.
V01
V03
V04
V05
V02
V06
V07
V08
V09
Feed
Tank
Filtrate
Tank
CIP
CEB
Air
U
F
Feed
Pump
(P01)
Backwash
Pump
(P02)
CIP
Pump
(P03)
CEB
Pump
(P04)
Discharge
Discharge
Chemicals
+ Water
Chemicals
Feed
Water
Filtrate
Pre-
Filter