range starting hour and minutes, 

 

range ending hour and minutes, 

 

icon (if no icon is visible, turn the knob counterclockwise). 

After  confirming  the  icon,  P  with  a  proper  number  is  displayed  again.  The  thermostat  will 
automatically  arrange  the  ranges  in  the  proper  sequence;  therefore  their  numbering  may 
change. 
When P1 is flashing, the knob may be turned to check  other ranges of the same day. Exit 
editing by holding OK longer. Return the operating window by holding OK again. Exiting in 
this way does not enable storing the introduced changes. 

 

In order to store the changes, exit editing with STORE option. 

Duration of ranges. P0

 

Manually  established  range  may  not  be  shorter  than  5 minutes  and  may  not  exceed 
24 hours.  However,  it  may  start  on  one  day  and  end  on  the  next  one.  This  enables 
establishing a range starting in the evening and ending in the morning. 
In such case an additional number will be visible: P0. It is only informative. This range does 
not limit a new day and the hour of starting the first range may be set freely.

 

Deleting ranges

 

Time ranges must last for at least 5 minutes.  
Setting a range lasting for a time shorter than 5 minutes leads to deleting it. 
Please remember: there will be a pause in heating in the place of the deleted range. 
Adding  a  new  range  with  starting  and  ending  hours  completely  overlapping  another  range 
also deletes the previous one. 
A range set up with the same starting and ending hour will be effective for 24 hours.

 

Automatic shifting of range limits

 

If  a  starting  or  ending  hour  of  a  new  range  overlaps  a  different,  previously  established 
range, then the preprogrammed one will be automatically shortened.

 

a.

 

COPY 

 (item 203)

 

 copying all settings from one day to another or several other days 

In order to copy any day to another or several other days, select COPY (item 203). Use the 
knob to select a day from which the settings will be copied. Confirm the selection. PASTE TO 
DAY is displayed. Use the knob to select a day or days to which the settings will be pasted. 
Confirm.  After  selecting  all  days  to  have  the  same  ranges,  turn  the  knob  clockwise  until 
STORE appears and confirm.

 

5. OPERATION MODES

 

 VACATION, AIRING, PARTY, HOLD, ECO

 

The thermostat enables manual activation of different operation modes. Settings available in 
MODES (item 1) menu adjust the operation to the current user needs and do not alter the 
programmed ranges.  
 

1.

 

VACATION 

 

  (item 101)

 

  setting  any  temperature  for  a  longer  period  (several 

hours, weeks or months), e.g. due to absence. It may start on the day of setting or in 
future, e.g. in a month or even a year time and may last for any required period. 

Содержание Q7TXRXGW

Страница 1: ...TAT MAINTENANCE Do not use the thermostat in rooms with excessive humidity significant dustiness or with presence of caustic or flammable vapors If necessary wipe it carefully with a damp cloth Do not...

Страница 2: ...e battery compartment II USER FUNCTIONS 1 CONTROL OF THE THERMOSTAT a Display icons and operating window 1 Hour 2 Strength of radio communication between the thermostat and the receiver 3 Text box 4 C...

Страница 3: ...fter pressing OK shortly when the display backlight is switched off If the thermostat cooperates with several receivers then the displayed signal strength is the signal strength of the most distant th...

Страница 4: ...sensor only e RX receiver The receiver is equipped with a pass through socket enabling connecting a boiler or other device to the power supply It is not a controllable socket It is a simple 230 V soc...

Страница 5: ...A will be displayed and the connected device will be switched on for 20 minutes every 3 h 2 BASIC SETTINGS The main menu consists of three basic items MODES 1 PROGRAMS 2 SERVICE 3 The menu items with...

Страница 6: ...P1 23 C 06 00 am 08 30 am P2 28 C 08 30 am 03 00 pm P3 22 C 03 00 pm 11 00 pm P4 25 C 11 00 pm 06 00 am Sat Sun P1 23 C 06 00 am 11 00 am P2 22 C 11 00 am 04 00 pm P3 23 C 04 00 pm 11 00 pm P4 25 C 1...

Страница 7: ...24 h The thermostat provides two methods of manual temperature setting a First method selecting an exact temperature for one of the three preset duration values It enables selecting the exact temperat...

Страница 8: ...ll days of the week 1 2 3 4 5 6 7 are flashing Select the proper day or group of days and confirm After selecting the device will automatically proceed to the next item EDIT item 202 b EDIT item 202 p...

Страница 9: ...se remember there will be a pause in heating in the place of the deleted range Adding a new range with starting and ending hours completely overlapping another range also deletes the previous one A ra...

Страница 10: ...TO mode Detection of a rapid drop of ambient temperature switches the heating device off for the preset time If frost protection temperature is not switched on item 308 NO then airing mode limits the...

Страница 11: ...mes and temperatures to be selected with the button see II User functions point 3 TEMPERATURE three temperatures of manual setting factory setting 18 C 20 C and 22 C DURATION three duration values of...

Страница 12: ...as established and repeated When learning is active item 306 YES the thermostat records the temperature and time when it was modified If similar temperatures differing by no more than 0 4 C will be se...

Страница 13: ...g days to properly calculate times for various temperatures thus for the first days the calculated times may not be enough to achieve precisely the preset temperatures at established times Usually the...

Страница 14: ...he settings entered in the technician s menu neither does it reset the date and time It deletes all settings in the SERVICE menu along with the programmed ranges 12 AIR CONDITIONING item 312 switch fr...

Страница 15: ...y algorithms to the particular configuration without the need to modify them manually in the service menu RADIO item 3 enables pairing devices establishing number of transmitters or receivers assignin...

Страница 16: ...mperature drops below the preset one in the three rooms with thermostats no 1 2 and 3 When turn off if any is set and no 4 is selected then the receiver will switch on the heating if the preset temper...

Страница 17: ...sh the priorities and possibly select a channel In order to pair Enter PAIR item and press OK WAIT will be displayed Then hold the left button of the RX receiver for 3 s PROG will be displayed Then ho...

Страница 18: ...he need to change over the cables push the right button shortly To switch on pairing hold the middle button longer To exit hold the left button longer V INSTALLATION AND CONNECTION 1 PROPER PLACE OF I...

Страница 19: ...rate the front panel and the base 3 SAMPLE CONNECTION DIAGRAMS The following diagrams are simplified and do not cover all the elements necessary for the correct installation In arrangement with a 230...

Страница 20: ...INSTALLATION AND OPERATION MANUAL 20 In arrangement with a central heating pump 1 CH boiler 2 CH pump 3 Heat consumer radiator 4 Electrical connection block 5 Euroster RXGW 6 Euroster Q7TX 7 Output c...

Страница 21: ...e Mounting method thermostat stand receiver 230 V 50 Hz socket Thermostat weight without batteries thermostat without batteries 114 g receiver 359 g Warranty period 2 years Dimensions W H D mm the the...

Страница 22: ...may be repaired exclusively by the manufacturer or by other party clearly authorized by the manufacturer 5 Warranty becomes invalidated in case of any mechanical damage incorrect operation and or maki...

Отзывы: