It  is  possible  to  connect  two  receivers,  one  for  the  heating  and  the  other  for  the  air-
conditioning device (see III. Service functions point 12). 
The  operation  with  several  TX  thermostats  is  possible  only  when  value  of  1  is  selected. 
NUMBER  OF  TX  option  will  be  available.  When  value  of  2  or  higher  is  selected  then  the 
option NUMBER OF TX will not be available.

 

d.

 

CHANNEL

 

 in exceptional cases it is possible that some external interference will affect 

the operation of the thermostats. Therefore, the set enables selecting the radio channel 
for  it  to  operate  at.  Any  channel  from  0  to  4  may  be  selected.  After  changing  the 
channel, the set should be paired again. The channels should be changed only when the 
conditions dictate.

 

e.

 

PAIR 

  each  thermostat  and  each  receiver  has  a  unique  no.  distinguishing  it  from  the 

other ones. It is not possible for any thermostat not paired with the particular receiver to 
interfere  with  the  operation  of  another  pair  or  set.  Therefore,  none  of  the  thermostats 
requires  assigning  a  separate  code  or  number.  Any  wireless  Q7TX  thermostat  may  be 
paired with any Q7RX receiver. 

 

Factory-established  pairs  are  paired,  however  pairing  may  be  repeated  if 
necessary. 

 

A thermostat may be paired with other receivers or several thermostats may be paired with 
one  RX  any  time.  A  blackout,  battery  replacement  as  well  as  a  complete  reset  of  all 
thermostat settings do not affect pairing of devices in any way. 
Prior to pairing select a subsequent no., then enter number of TX and RX, in case of several 
TX establish the priorities and possibly select a channel. 
In order to pair: 

 

Enter PAIR item and press OK; WAIT... will be displayed; 

 

Then hold the left button of the RX receiver for 3 s; PROG will be displayed; 

 

Then hold the middle button longer; "P" letter will be displayed; 

 

Release the button and pairing will be complete. 

Both devices should resume normal operation. When the thermostat backlight goes off, then 
the current signal strength transmitted from the thermostat is displayed at the receiver. 
When several thermostats are to cooperate with one receiver WAIT... must be displayed at 
all of them, after that activate pairing at the receiver.  
When several receivers are to cooperate with one thermostat, the thermostat will complete 
pairing when all receivers are synchronized.

 

f.

 

COPY TO RX

 

 all thermostat settings are stored in the receiver. This enables restoring 

all  stored  settings  in  case  of  thermostat  replacement.  The  settings  are  stored 
automatically at least once a day, however  this function enables storing the settings at 
any time.

 

g.

 

COPY  FROM  RX

 

  enables  transfer  of  the  previously  stored  settings  to  the  new 

thermostat or to the reset one. 

The function is particularly useful for the technicians who frequently install thermostats with 
their  own  well-proven  settings.  It  enables  the  technicians  to  avoid  entering  the  same 
settings  every  time.  It  is  enough  for  the  technician  to  have  his  own  RX  receiver  with  the 
previously  stored  settings,  e.g.  the  ranges,  then  pair  the  thermostat  of  the  client  with  his 
own  receiver and copy  his own settings to the new TX. If the devices are paired  for  more 
than  30 minutes  and  if  the  technician  will  not  copy  his  settings  within  this  time,  then  the 
factory  settings  from  the  new  thermostat  may  replace  the  settings  in  the  technician's 
thermostat. 

Содержание Q7TXRXGW

Страница 1: ...TAT MAINTENANCE Do not use the thermostat in rooms with excessive humidity significant dustiness or with presence of caustic or flammable vapors If necessary wipe it carefully with a damp cloth Do not...

Страница 2: ...e battery compartment II USER FUNCTIONS 1 CONTROL OF THE THERMOSTAT a Display icons and operating window 1 Hour 2 Strength of radio communication between the thermostat and the receiver 3 Text box 4 C...

Страница 3: ...fter pressing OK shortly when the display backlight is switched off If the thermostat cooperates with several receivers then the displayed signal strength is the signal strength of the most distant th...

Страница 4: ...sensor only e RX receiver The receiver is equipped with a pass through socket enabling connecting a boiler or other device to the power supply It is not a controllable socket It is a simple 230 V soc...

Страница 5: ...A will be displayed and the connected device will be switched on for 20 minutes every 3 h 2 BASIC SETTINGS The main menu consists of three basic items MODES 1 PROGRAMS 2 SERVICE 3 The menu items with...

Страница 6: ...P1 23 C 06 00 am 08 30 am P2 28 C 08 30 am 03 00 pm P3 22 C 03 00 pm 11 00 pm P4 25 C 11 00 pm 06 00 am Sat Sun P1 23 C 06 00 am 11 00 am P2 22 C 11 00 am 04 00 pm P3 23 C 04 00 pm 11 00 pm P4 25 C 1...

Страница 7: ...24 h The thermostat provides two methods of manual temperature setting a First method selecting an exact temperature for one of the three preset duration values It enables selecting the exact temperat...

Страница 8: ...ll days of the week 1 2 3 4 5 6 7 are flashing Select the proper day or group of days and confirm After selecting the device will automatically proceed to the next item EDIT item 202 b EDIT item 202 p...

Страница 9: ...se remember there will be a pause in heating in the place of the deleted range Adding a new range with starting and ending hours completely overlapping another range also deletes the previous one A ra...

Страница 10: ...TO mode Detection of a rapid drop of ambient temperature switches the heating device off for the preset time If frost protection temperature is not switched on item 308 NO then airing mode limits the...

Страница 11: ...mes and temperatures to be selected with the button see II User functions point 3 TEMPERATURE three temperatures of manual setting factory setting 18 C 20 C and 22 C DURATION three duration values of...

Страница 12: ...as established and repeated When learning is active item 306 YES the thermostat records the temperature and time when it was modified If similar temperatures differing by no more than 0 4 C will be se...

Страница 13: ...g days to properly calculate times for various temperatures thus for the first days the calculated times may not be enough to achieve precisely the preset temperatures at established times Usually the...

Страница 14: ...he settings entered in the technician s menu neither does it reset the date and time It deletes all settings in the SERVICE menu along with the programmed ranges 12 AIR CONDITIONING item 312 switch fr...

Страница 15: ...y algorithms to the particular configuration without the need to modify them manually in the service menu RADIO item 3 enables pairing devices establishing number of transmitters or receivers assignin...

Страница 16: ...mperature drops below the preset one in the three rooms with thermostats no 1 2 and 3 When turn off if any is set and no 4 is selected then the receiver will switch on the heating if the preset temper...

Страница 17: ...sh the priorities and possibly select a channel In order to pair Enter PAIR item and press OK WAIT will be displayed Then hold the left button of the RX receiver for 3 s PROG will be displayed Then ho...

Страница 18: ...he need to change over the cables push the right button shortly To switch on pairing hold the middle button longer To exit hold the left button longer V INSTALLATION AND CONNECTION 1 PROPER PLACE OF I...

Страница 19: ...rate the front panel and the base 3 SAMPLE CONNECTION DIAGRAMS The following diagrams are simplified and do not cover all the elements necessary for the correct installation In arrangement with a 230...

Страница 20: ...INSTALLATION AND OPERATION MANUAL 20 In arrangement with a central heating pump 1 CH boiler 2 CH pump 3 Heat consumer radiator 4 Electrical connection block 5 Euroster RXGW 6 Euroster Q7TX 7 Output c...

Страница 21: ...e Mounting method thermostat stand receiver 230 V 50 Hz socket Thermostat weight without batteries thermostat without batteries 114 g receiver 359 g Warranty period 2 years Dimensions W H D mm the the...

Страница 22: ...may be repaired exclusively by the manufacturer or by other party clearly authorized by the manufacturer 5 Warranty becomes invalidated in case of any mechanical damage incorrect operation and or maki...

Отзывы: