EUROSTER Q7TXRXGW Скачать руководство пользователя страница 12

EUROSTER Q7TXRX

GW

 

 INSTALLATION AND OPERATION MANUAL

 

12

 

 

 

 

PWM CYCLES 

 allowable number of cycles during one hour is from 2 to 20. An hour 

divided by the number of cycles gives duration of one full cycle. 

 

MIN. PWM TIME 

 minimum duration of one cycle: from 1 to 10 minutes. In case of 

using devices that require a minimum start-up time or an operation lasting not less 
than a specific period, take it into account and adjust this parameter properly. 

 

PWM LIMIT 

 

from 0.1 to 10ºC –

 when the room temperature drops below the preset 

one  by  a  whole  limit  value,  then  the  heating  device  is  switched  on  for  a  complete 
cycle;  when  the  temperature  increases,  then  the  cycle  is  shortened  proportionally 
and the time intervals between the switch-ons are lengthened. 

 

6.

 

LEARNING  (item 306)

 

  automatic  storing  of  selected  temperatures  and  their  time 

ranges (see: Section II. User functions, point 2c.) 

The thermostat stores the duration of a preset temperature and automatically establishes a 
time range in which this temperature is effective. This range will be effective for all days of 
the  Mon-Fri  period  or  Sat-Sun  period  depending  on  the  period  in  which  the  setting  was 
established and repeated.  
 
When learning is active (item 306 

 YES), the thermostat records the temperature and time 

when it was modified.  

If  similar  temperatures  (differing  by  no  more  than  0.4ºC)  will  be  set  by  a  user  at  similar 

times (time difference not exceeding 60 minutes) in subsequent days of the Mon-Fri or Sat-
Sun period, then such manual setting will be stored in the PROGRAMS menu (item 2). It will 
be  implemented  automatically.  Time  ranges  are  rounded  by  the  learning  mode  to  full  ten 
minutes. 
Settings for the individual days of the week are also stored and if they are repeated, e.g. on 
two subsequent Mondays or two subsequent Saturdays, then such setting will also be stored 
in the programs. It will be implemented always on these particular weekdays.

 

After switching the learning mode off and on again, all stored ranges and programs 
are deleted.

 

 

Maximum number of ranges per day: 9 

 

Minimum duration: 60 minutes, maximum: 24 h 

New  ranges  are  established  during  first  four  weeks  only.  In  that  period  the  symbol  of  the 
first  stage  [I]  will  be  visible  in  the  text  box.  After  that  period,  learning  proceeds  to  the 
second stage [II], in which new ranges may not be added. One may only shift the limits of 
already stored ranges  and change their temperatures. Since then [II] icon is  visible in the 
text box.

 

 

The stored ranges may be modified any time by: 

Содержание Q7TXRXGW

Страница 1: ...TAT MAINTENANCE Do not use the thermostat in rooms with excessive humidity significant dustiness or with presence of caustic or flammable vapors If necessary wipe it carefully with a damp cloth Do not...

Страница 2: ...e battery compartment II USER FUNCTIONS 1 CONTROL OF THE THERMOSTAT a Display icons and operating window 1 Hour 2 Strength of radio communication between the thermostat and the receiver 3 Text box 4 C...

Страница 3: ...fter pressing OK shortly when the display backlight is switched off If the thermostat cooperates with several receivers then the displayed signal strength is the signal strength of the most distant th...

Страница 4: ...sensor only e RX receiver The receiver is equipped with a pass through socket enabling connecting a boiler or other device to the power supply It is not a controllable socket It is a simple 230 V soc...

Страница 5: ...A will be displayed and the connected device will be switched on for 20 minutes every 3 h 2 BASIC SETTINGS The main menu consists of three basic items MODES 1 PROGRAMS 2 SERVICE 3 The menu items with...

Страница 6: ...P1 23 C 06 00 am 08 30 am P2 28 C 08 30 am 03 00 pm P3 22 C 03 00 pm 11 00 pm P4 25 C 11 00 pm 06 00 am Sat Sun P1 23 C 06 00 am 11 00 am P2 22 C 11 00 am 04 00 pm P3 23 C 04 00 pm 11 00 pm P4 25 C 1...

Страница 7: ...24 h The thermostat provides two methods of manual temperature setting a First method selecting an exact temperature for one of the three preset duration values It enables selecting the exact temperat...

Страница 8: ...ll days of the week 1 2 3 4 5 6 7 are flashing Select the proper day or group of days and confirm After selecting the device will automatically proceed to the next item EDIT item 202 b EDIT item 202 p...

Страница 9: ...se remember there will be a pause in heating in the place of the deleted range Adding a new range with starting and ending hours completely overlapping another range also deletes the previous one A ra...

Страница 10: ...TO mode Detection of a rapid drop of ambient temperature switches the heating device off for the preset time If frost protection temperature is not switched on item 308 NO then airing mode limits the...

Страница 11: ...mes and temperatures to be selected with the button see II User functions point 3 TEMPERATURE three temperatures of manual setting factory setting 18 C 20 C and 22 C DURATION three duration values of...

Страница 12: ...as established and repeated When learning is active item 306 YES the thermostat records the temperature and time when it was modified If similar temperatures differing by no more than 0 4 C will be se...

Страница 13: ...g days to properly calculate times for various temperatures thus for the first days the calculated times may not be enough to achieve precisely the preset temperatures at established times Usually the...

Страница 14: ...he settings entered in the technician s menu neither does it reset the date and time It deletes all settings in the SERVICE menu along with the programmed ranges 12 AIR CONDITIONING item 312 switch fr...

Страница 15: ...y algorithms to the particular configuration without the need to modify them manually in the service menu RADIO item 3 enables pairing devices establishing number of transmitters or receivers assignin...

Страница 16: ...mperature drops below the preset one in the three rooms with thermostats no 1 2 and 3 When turn off if any is set and no 4 is selected then the receiver will switch on the heating if the preset temper...

Страница 17: ...sh the priorities and possibly select a channel In order to pair Enter PAIR item and press OK WAIT will be displayed Then hold the left button of the RX receiver for 3 s PROG will be displayed Then ho...

Страница 18: ...he need to change over the cables push the right button shortly To switch on pairing hold the middle button longer To exit hold the left button longer V INSTALLATION AND CONNECTION 1 PROPER PLACE OF I...

Страница 19: ...rate the front panel and the base 3 SAMPLE CONNECTION DIAGRAMS The following diagrams are simplified and do not cover all the elements necessary for the correct installation In arrangement with a 230...

Страница 20: ...INSTALLATION AND OPERATION MANUAL 20 In arrangement with a central heating pump 1 CH boiler 2 CH pump 3 Heat consumer radiator 4 Electrical connection block 5 Euroster RXGW 6 Euroster Q7TX 7 Output c...

Страница 21: ...e Mounting method thermostat stand receiver 230 V 50 Hz socket Thermostat weight without batteries thermostat without batteries 114 g receiver 359 g Warranty period 2 years Dimensions W H D mm the the...

Страница 22: ...may be repaired exclusively by the manufacturer or by other party clearly authorized by the manufacturer 5 Warranty becomes invalidated in case of any mechanical damage incorrect operation and or maki...

Отзывы: