EUROSTER 11K CONTROLLER USER MANUAL

7

k) Relay activation delay

To increase lifetime of the controller output relays, outputs are prevented against activating/
deactivating   more  frequently   than   once   per   second.   However,  lights  signaling   state   of the

relays go on/off without any delay.

l) Output tests

The 

t1, t2, t3, tP, Ta

 installer parameters may be used to manually turn on/off the 

P1, P2,

P3

 pumps, throttle, and 

AUX

 outputs, respectively (to test them).

5. SETUP
a) User parameters

User parameters are system settings (temperature presets) that may be modified by the user.

Use the

  button to sequentially display preset temperature thresholds at which P1/P2/P3

pump, throttle, and  

AUX

 output are activated (press the button to display next preset). Use

the  

  and  

  buttons to modify the displayed value. Each modification must be confirmed

with the

button  or else the controller cancels it after 10 seconds. Use the  

  button to

cancel errors.
Only   user  parameters   used   in   the   given   system   layout   are   displayed,   those   not   used   are

hidden. User parameters include:

P1

Temperature at which the P1 pump is engaged. Range: 20÷85°C. Standard
value: 40°C.

P2

Temperature at which the P2 pump is engaged. Range: 20÷85°C. Standard
value: 40°C. Only for layouts 2 and 3.

P3

Temperature at which the P3 pump is engaged. Range: 20÷85°C. Standard
value: 45°C. Only for layouts 2 and 3.

THROTTLE

Preset fireplace temperature (throttle activation threshold). Range: (20 or

tb

)÷(70 or 

OH

–5°C). Standard value: 55°C.

AUX

Temperature   at   which   the  

AUX

  output   is   deactivated.   Range:   20÷85°C.

Standard value: 35°C.

b) Installer parameters (service mode settings)
ATTENTION  Installer   parameters  must   be  modified   knowledgeably  or  else  the  CH

system may start to work incorrectly. Therefore the parameters should be modified
exclusively by a qualified installer/serviceman.

Simultaneously press and hold the  

and

buttons to enter the service setup mode. Code

(symbol) of the first installer parameter is displayed. Use the  

  and  

  buttons to display

other parameters. Use the 

 button to display current value of the displayed parameter. Use

the  

  and  

  buttons to modify the displayed value. Each modification must be confirmed

with the

button or else the controller will cancel it after 1 minute. Use the  

  button to

cancel errors.

Installer   parameters   (system   settings   that   should   be   modified   only   by   a   qualified
installer/serviceman) include: 

H1

P1

  threshold hysteresis ( i.e. difference between temperature at which the P1

pump is engaged and temperature at which the pump is disengaged). Range:
1÷10°C. Standard value: 5°C.

H2

P2

 threshold hysteresis. Range: 1÷10°C. Standard value: 5°C.

H3

P3

 threshold hysteresis. Range: 1÷10°C. Standard value: 5°C.

HP

Throttle threshold hysteresis. Range: 1÷10°C. Standard value: 5°C.

HA

AUX

 output threshold hysteresis. Range: 1÷10°C. Standard value: 5°C.

tE

Put-out   temperature.   Range:   30÷(40   or  

tb

–10)°C.   Standard   value:   30°C.

Содержание 11K

Страница 1: ...he controller may control systems built according to one of the three following layouts CH system with a plate heat exchanger CH system with a heat buffer CH system with a plate heat exchanger and a DWH tank In all layouts the controller adjusts the combustion processes by opening closing the fireplace throttle depending on the measured temperatures and information received from the cooperating ro...

Страница 2: ... the controller off 2 decrement the displayed value turn the ignition off 3 increment the displayed value turn the ignition on 4 accept the displayed value turn the controller on enter the setup mode 3 INSTALLATION ATTENTION Hazardous voltages may be present inside the controller and on its cables Therefore it is expressly forbidden to install the device unless its mains power supply is disconnect...

Страница 3: ...e the controller power supply cord must be unplugged before any works are started The procedure a Mount the S1 sensor do not immerse the sensor into any liquid nor install it within chimney flue gas stream install sensor at some external surface of the fireplace water jacket or on an uncovered segment of the fireplace outlet pipe as close to the fireplace as possible using a hose clip tighten the ...

Страница 4: ...actuated by a 230 VAC actuator In absence of power the throttle should close automatically connect protective wires of the pumps and of the throttle with the PE power cord wire ATTENTION Controller is a 2nd insulation class device so it needs no grounding However every cooperating device that needs to be grounded must be obligatorily connected to the protective wire f Hook up power supply cable co...

Страница 5: ... that not happen within 1 hour the controller will cancel the ignition function and close the throttle Otherwise it will resume normal operation Activation of the ignition function is signaled by the light The function is activated automatically once the controller is turned on It may also be activated manually using the button Press the button to deactivate the ignition function e Cooperation wit...

Страница 6: ...output is equipped with both normally open NO and normally closed NC contacts In case of an alarm mains voltage normally connected to the NC contact is switched over to the NO contact h Acoustic alarm Should the fireplace water jacket CH tank temperature exceed the alarm threshold an acoustic alarm signal is activated Press any button to stop the signal for 5 minutes i The ANTY STOP function The A...

Страница 7: ...ayouts 2 and 3 THROTTLE Preset fireplace temperature throttle activation threshold Range 20 or tb 70 or OH 5 C Standard value 55 C AUX Temperature at which the AUX output is deactivated Range 20 85 C Standard value 35 C b Installer parameters service mode settings ATTENTION Installer parameters must be modified knowledgeably or else the CH system may start to work incorrectly Therefore the paramet...

Страница 8: ...eds the tE threshold OF Automatic shut down delay Range 0 30 min Standard value 5 min The controller will shut down automatically OF minutes after the time when the fireplace temperature has dropped down below the tE threshold OF 0 the controller will never shut down automatically C1 S1 sensor offset Range 5 5 C Standard value 0 C That parameter may be used to correct temperature readings C2 S2 se...

Страница 9: ...d with a delay in respect to P1 activation time if the fireplace temperature exceeds the preset temperature P3 alarm output is activated if the fireplace temperature exceeds the critical temperature AUX output is deactivated if the fireplace temperature exceeds the AUX temperature or RT is turned off Throttle is controlled open closed to maintain the preset temperature b Layout 2 CH system with he...

Страница 10: ...ICATES The E11K controller meets all requirements of the EMC and the LVD EU Directives The CE Conformity Declaration is available on the http www euroster com pl Internet webpage 8 SPECIFICATIONS a Temperature range 0 C 99 C b Mains 230 V 50 Hz c Combined current consumption max 3 A d Case flush fitting 4M electrical box 4 KIT CONTENTS a Euroster 11K controller b S1 temperature sensor with 2 m lon...

Страница 11: ... may be repaired exclusively by the manufacturer or by other party clearly authorized by the manufacturer 5 Warranty becomes invalidated in case of any mechanical damage incorrect operation and or making any repairs by unauthorized persons 6 This consumer warranty does not exclude restrict nor suspend any right of the Buyer ensuing if the product would not meet any of the sale contract terms sale ...

Отзывы: