c) Layout 3 : CH system with plate heat exchanger and DWH tank
ATTENTION Since in the 3
rd
layout heat surplus is transferred to the DWH
tank, temperature of water in that tank may theoretically reach the critical
threshold (as preset by the OH installer parameter value).
P1
pump is activated if the fireplace temperature exceeds the preset temperature
P2
pump is activated if the fireplace temperature exceeds the preset temperature and
the
RT
signal is ON and the DWH priority is not active
P3
pump is activated if the tank temperature drops down and the fireplace temperature
is sufficiently higher than the tank temperature
AUX
output is deactivated if the fireplace temperature exceeds the
AUX
temperature or
RT
is turned off
Throttle is controlled (open/closed) to maintain the preset temperature.
7. COMPATIBILITY WITH STANDARDS AND CERTIFICATES
The E11K controller meets all requirements of the EMC and the LVD EU Directives. The CE
Conformity Declaration is available on the http://www.euroster.com.pl Internet webpage.
8. SPECIFICATIONS
a) Temperature range
0°C – 99°C
b) Mains
230 V 50 Hz
c) Combined current consumption
max. 3 A
d) Case
flush-fitting 4M electrical box
4. KIT CONTENTS
a) Euroster 11K controller
b) S1 temperature sensor with 2 m long silicone-insulated cable
c) S2 temperature sensor with 2.5 m long cable
d) sensor hose clips
e) this Installation & Operation Manual
ELECTRONIC WASTE MANAGEMENT INFORMATION
We made every effort to get as long controller lifetime as possible. However,
the device is subject to natural tear and wear. We ask you to have a
controller that will not meet your requirements any more brought into an
electronic waste management facility. Electronic waste is collected free of
charge by local distributors of electronic equipment.
Inappropriate management of electronic waste may lead to an unnecessary
environment pollution.
Cardboard boxes should be disposed of at a paper recycling facility.