EUROSTER 11E USER MANUAL

2

wall (or any other suitable supporting structure)

using fasteners fix controller cables to the wall.

b) Install temperature sensors:

do not immerse sensors in liquids nor install them within stream of flue gases 

install boiler temperature sensor at the boiler point specially designed for that purpose 

or else on an unshielded boiler outlet pipe (as close to the boiler as possible) or install 
UHW tank temperature sensor at the tank point specially designed for that purpose 

using hose clips tighten the sensor to its pipe and cover it with thermal insulation.

c) Hook up pump power supply cable:

connect yellow (or yellow-green) PE wire with the 

 terminal

connect blue wire with the N terminal

connect brown wire with the L terminal.

d) Verify the connections:

check up all cable connections and tighten terminal box lids. 

e) Hook up the controller:

make sure controller cables are protected against incidental cut off

plug the controller power supply cable into a 230V/50Hz mains socket equipped with a 

grounding pin.  

The controller must not be installed in a place where the ambient 
temperature may exceed 40ºC.

5

CONTROLLER DISPLAY

Elements of the controller display:

1. Name of the controlled parameter (displayed while set point values are browsed/set)

2. Heat source (boiler) temperature sensor icon (CH system control mode)
3. Manual operation mode (icon lit while the temperature is manually controlled)

4. Alarm (icon blinks in case of an alarm)
5. State of the heat source (boiler) furnace – animated icon, see description below

6. UHW system pump icon lit while the pump is running (UHW system control mode)
7. CH system pump icon lit while the pump is running (CH system control mode)

8. Heat source (boiler)/UHW tank temperature (CH system/UHW system control mode, 

respectively) / other displayed parameter value 

9. UHW tank temperature sensor icon (UHW system control mode)
10. Menu option number (displayed while set point values are browsed/set)

Animated icon that visually presents state of the heat source (boiler) furnace is for 

information purposes only, it does not influence operation of the controller in any 

Содержание 11E

Страница 1: ...gainst seizing Once the heating season is over every 14 days the function automatically turns ON the pumps for 30 seconds To that end the controller must be left powered up 3 VISIBLE CONTROLLER ELEMEN...

Страница 2: ...power supply cable into a 230V 50Hz mains socket equipped with a grounding pin The controller must not be installed in a place where the ambient temperature may exceed 40 C 5 CONTROLLER DISPLAY Eleme...

Страница 3: ...s to change the mode Set 1 has been complied for layouts in which CH system pump is controlled Set 2 has been complied for layouts in which UHW pump is controlled Proceed as follows to restore factory...

Страница 4: ...0 80 80 C Pump hysteresis 4 4 2 2 10 10 C Temperature sensor correction 0 0 5 5 5 5 C Pump manual operation test as calculated by the controller as calculated by the controller 0 OFF 0 OFF 1 ON 1 ON 9...

Страница 5: ...d a odwo ania Check pump connection d Controller knob operates erratically Pulse generator failure Have the controller serviced 12 COMPATIBILITY WITH STANDARDS CERTIFICATES The EUROSTER 11E controller...

Страница 6: ...operate the system is shown Central heating pump control mode 1 EUROSTER 11E controller 2 CH boiler 3 Heat source temperature sensor 4 CH pump 5 Radiator heat load Utility hot water pump control mode...